Ultrasound-enhanced water electrolysis for hydrogen production: Mechanisms, metrology and energy metrics

Ultrasound intensifies hydrogen production in water electrolysis cells by thinning boun­dary layers, accelerating bubble detachment, and, in tuned windows, modulating cavi­tation chemistry, yet cross-study claims remain difficult to compare. Focusing on ultra­sound-enhanced water electrolysis (sono-electrolysis), this review aligns reporting with IEC 61161 (radiation-force acoustic power) and IEC 62127-2:2025 (hydrophone calibra­tion); requires delivered acoustic intensity at the electrode, Idel / W·cm⁻², with stated trace­ability; pairs isothermal control with uncertainty budgets; and benchmarks perfor­mance using Δ-metrics: Δj (current-density gain at fixed cell voltage), Δη (cell voltage/over­po­tential reduction at fixed current density) and ΔH₂ (hydrogen production rate gain at matched electrical input), together with specific energy consumption (SEC, kWh·kg⁻¹ H₂). A window-based synthesis indicates that, under isothermal operation, 20 to 40 kHz with delivered intensity ≈0.2 to 1.0 W·cm⁻² reproducibly yields Δj ≈ 15 to 30 %, Δη ≈ 40 to 120 mV, ΔH₂ ≈ 10 to 30 %, and net SEC improvements of ~8 to 12 % when auxiliary loads are included, whereas at higher dose (Idel ≈ 1.0 to 1.6 W·cm⁻²) non-uniform fields, cloud shielding, and heating can saturate or reverse benefits. To prevent metric conflation, hybrid sono-hydrogen routes are reviewed separately. The review concludes by proposing a minimum reporting set-frequency, waveform/duty and pulse repetition frequency, Idel (traceability/uncertainty), geometry/stand-off, electrolyte and dissolved gas, bulk tempe­rature and runtime, gas metrology with temperature/pressure cor­rections, SEC boun­daries and replicates/statistics, and by outlining priorities for operando cavitation-electro­chemistry co-registration, geometry/void-fraction-aware scale-up, and durability under combined fields, to support reproducible, energy-accounted, and comparable studies across laboratories.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Science and Engineering
Published
2026-01-20
DOI
https://doi.org/10.5599/jese.3045
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound-enhanced water electrolysis for hydrogen production: Mechanisms, metrology and energy metrics

Heoy Geok How, Yew Heng Teoh, Thanh Danh Le, Mohamad Yusof Idroas et al.
Journal of Electrochemical Science and Engineering
Ultrasound and Cavitation Phenomena
article

Ultrasound-enhanced water electrolysis for hydrogen production: Mechanisms, metrology and energy metrics

Heoy Geok How, Yew Heng Teoh, Thanh Danh Le, Mohamad Yusof Idroas, ChenHongWen Zeng
article en

Abstract

Ultrasound intensifies hydrogen production in water electrolysis cells by thinning boun­dary layers, accelerating bubble detachment, and, in tuned windows, modulating cavi­tation chemistry, yet cross-study claims remain difficult to compare. Focusing on ultra­sound-enhanced water electrolysis (sono-electrolysis), this review aligns reporting with IEC 61161 (radiation-force acoustic power) and IEC 62127-2:2025 (hydrophone calibra­tion); requires delivered acoustic intensity at the electrode, Idel / W·cm⁻², with stated trace­ability; pairs isothermal control with uncertainty budgets; and benchmarks perfor­mance using Δ-metrics: Δj (current-density gain at fixed cell voltage), Δη (cell voltage/over­po­tential reduction at fixed current density) and ΔH₂ (hydrogen production rate gain at matched electrical input), together with specific energy consumption (SEC, kWh·kg⁻¹ H₂). A window-based synthesis indicates that, under isothermal operation, 20 to 40 kHz with delivered intensity ≈0.2 to 1.0 W·cm⁻² reproducibly yields Δj ≈ 15 to 30 %, Δη ≈ 40 to 120 mV, ΔH₂ ≈ 10 to 30 %, and net SEC improvements of ~8 to 12 % when auxiliary loads are included, whereas at higher dose (Idel ≈ 1.0 to 1.6 W·cm⁻²) non-uniform fields, cloud shielding, and heating can saturate or reverse benefits. To prevent metric conflation, hybrid sono-hydrogen routes are reviewed separately. The review concludes by proposing a minimum reporting set-frequency, waveform/duty and pulse repetition frequency, Idel (traceability/uncertainty), geometry/stand-off, electrolyte and dissolved gas, bulk tempe­rature and runtime, gas metrology with temperature/pressure cor­rections, SEC boun­daries and replicates/statistics, and by outlining priorities for operando cavitation-electro­chemistry co-registration, geometry/void-fraction-aware scale-up, and durability under combined fields, to support reproducible, energy-accounted, and comparable studies across laboratories.

Journal of Electrochemical Science and Engineering
Universiti Sains Malaysia (MY), University of Economics Ho Chi Minh City (VN), University of Wollongong Malaysia (MY)
Affordable and clean energy
Openalex Percentile: Top 83%
Ultrasound and Cavitation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.