Trust but verify: Image-aware evaluation of radiology report generators

Large language and vision-language models have greatly advanced automated chest X-ray report generation (RRG),. yet current evaluation practices remain largely text-based and detached from image evidence. Traditional machine translation metrics fail to determine whether generated findings are clinically correct or visually grounded, limiting their suitability for medical applications. This study introduces a comprehensive, image-aware evaluation framework that integrates the VICCA ( Visual Interpretation and Comprehension of Chest X-ray Anomalies ) protocol with the domain-specific semantic metric MCSE ( Medical Corpus Similarity Evaluation ). VICCA combines visual grounding and text-guided image generation to assess visual-textual consistency, while MCSE measures semantic and factual fidelity through clinically meaningful entities, negations, and modifiers. Together, they provide a unified, semi-reference-free assessment of pathology-level accuracy, semantic coherence, and visual consistency. Five representative RRG models, R2Gen, M2Trans, CXR-RePaiR, RGRG, and MedGemma, are benchmarked on 2461 MIMIC-CXR studies using a standardized pipeline. Results reveal systematic trade-offs: models with high pathology agreement often generate semantically weak or visually inconsistent reports, whereas textually fluent models may lack proper image grounding. By integrating clinical semantics and visual reliability within a single multimodal framework, VICCA establishes a robust paradigm for evaluating the trustworthiness and interpretability of AI-generated radiology reports. • Unified multimodal framework for radiology report evaluation. • Extends VICCA with domain-aware semantic metric MCSE. • Benchmarks five RRG models on MIMIC-CXR studies. • Reveals trade-offs between accuracy, semantics, and grounding. • Provides reproducible, image-aware evaluation guidelines.

Authors

Institutions

Publication Details

Journal
Machine Learning with Applications
Published
2026-01-20
DOI
https://doi.org/10.1016/j.mlwa.2026.100851
Primary Topic
Multimodal Machine Learning Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trust but verify: Image-aware evaluation of radiology report generators

Sayeh Gholipour Picha, Alice Caplier, Dawood Al Chanti
Machine Learning with Applications
Multimodal Machine Learning Applications
article

Trust but verify: Image-aware evaluation of radiology report generators

Sayeh Gholipour Picha, Alice Caplier, Dawood Al Chanti
article en

Abstract

Large language and vision-language models have greatly advanced automated chest X-ray report generation (RRG),. yet current evaluation practices remain largely text-based and detached from image evidence. Traditional machine translation metrics fail to determine whether generated findings are clinically correct or visually grounded, limiting their suitability for medical applications. This study introduces a comprehensive, image-aware evaluation framework that integrates the VICCA ( Visual Interpretation and Comprehension of Chest X-ray Anomalies ) protocol with the domain-specific semantic metric MCSE ( Medical Corpus Similarity Evaluation ). VICCA combines visual grounding and text-guided image generation to assess visual-textual consistency, while MCSE measures semantic and factual fidelity through clinically meaningful entities, negations, and modifiers. Together, they provide a unified, semi-reference-free assessment of pathology-level accuracy, semantic coherence, and visual consistency. Five representative RRG models, R2Gen, M2Trans, CXR-RePaiR, RGRG, and MedGemma, are benchmarked on 2461 MIMIC-CXR studies using a standardized pipeline. Results reveal systematic trade-offs: models with high pathology agreement often generate semantically weak or visually inconsistent reports, whereas textually fluent models may lack proper image grounding. By integrating clinical semantics and visual reliability within a single multimodal framework, VICCA establishes a robust paradigm for evaluating the trustworthiness and interpretability of AI-generated radiology reports. • Unified multimodal framework for radiology report evaluation. • Extends VICCA with domain-aware semantic metric MCSE. • Benchmarks five RRG models on MIMIC-CXR studies. • Reveals trade-offs between accuracy, semantics, and grounding. • Provides reproducible, image-aware evaluation guidelines.

Machine Learning with ApplicationsVol. 23
Université Grenoble Alpes (FR)
Quality Education
Openalex Percentile: Top 84%
Multimodal Machine Learning Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.