Portable Multichannel Measurement System for Real-Time Microplastics Assessment Using Microwave Sensors

This paper presents a multichannel electronics measurement system that uses microwave sensors to perform real-time microplastics assessment in aqueous environments. The system is capable of simultaneously reading up to four microwave sensors, enabling the use of multiple sensors that target microplastic particles with different sizes and properties. The multichannel capability allows the measurement of multiple MW sensors integrated with different microfluidic channel designs while targeting different MPs' dimension ranges, although experimental validation in this work was limited to a single sensor. Each readout channel is implemented combining radio-technology-integrated circuits with a microprocessor that has advanced analog peripherals used for signal conditioning and acquisition. An ADF4351 wideband frequency synthesizer is used for excitation signal generation while an ADL5902 power detector converts the sensor output to a DC voltage. Baseline removal and amplification of the power detector output is realized with a MSP430FR2355 microprocessor which is also responsible for its acquisition at 40 kHz and digital decimation. Characterization results show the system's capability to generate excitation signals between 700 MHz and 3.5 GHz with power levels around 0 dBm. Sensor output can be detected with a power between -50 dBm and -5 dBm and a 230 Hz bandwidth. A compact form factor of 15 cm × 10 cm × 3 cm was realized together with a low power consumption of 6.6 W. Validation was realized with a previously developed microwave sensor, demonstrating the detection of polyethylene spheres with 400 μm diameters animated in 10 mL/min flux within the microfluidics device.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-19
DOI
https://doi.org/10.3390/s26020669
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable Multichannel Measurement System for Real-Time Microplastics Assessment Using Microwave Sensors

André Barrancos, Jorge Assis, Diogo Rosinha, Luís S. Rosado
Sensors
Microplastics and Plastic Pollution
article

Portable Multichannel Measurement System for Real-Time Microplastics Assessment Using Microwave Sensors

André Barrancos, Jorge Assis, Diogo Rosinha, Luís S. Rosado
article en

Abstract

This paper presents a multichannel electronics measurement system that uses microwave sensors to perform real-time microplastics assessment in aqueous environments. The system is capable of simultaneously reading up to four microwave sensors, enabling the use of multiple sensors that target microplastic particles with different sizes and properties. The multichannel capability allows the measurement of multiple MW sensors integrated with different microfluidic channel designs while targeting different MPs' dimension ranges, although experimental validation in this work was limited to a single sensor. Each readout channel is implemented combining radio-technology-integrated circuits with a microprocessor that has advanced analog peripherals used for signal conditioning and acquisition. An ADF4351 wideband frequency synthesizer is used for excitation signal generation while an ADL5902 power detector converts the sensor output to a DC voltage. Baseline removal and amplification of the power detector output is realized with a MSP430FR2355 microprocessor which is also responsible for its acquisition at 40 kHz and digital decimation. Characterization results show the system's capability to generate excitation signals between 700 MHz and 3.5 GHz with power levels around 0 dBm. Sensor output can be detected with a power between -50 dBm and -5 dBm and a 230 Hz bandwidth. A compact form factor of 15 cm × 10 cm × 3 cm was realized together with a low power consumption of 6.6 W. Validation was realized with a previously developed microwave sensor, demonstrating the detection of polyethylene spheres with 400 μm diameters animated in 10 mL/min flux within the microfluidics device.

SensorsVol. 26(2)
University of Lisbon (PT), Instituto de Telecomunicações (PT)
Affordable and clean energy
Openalex Percentile: Top 84%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.