Conventional X-ray beam monitors, such as gold meshes and conductive diamond films, often suffer from significant drawbacks, as diffraction effects, non-uniform transparency, low signal levels, and poor spatial resolution, particularly when applied to soft and tender X-ray beams. To address these limitations, we explore the use of ultra-thin (<2 µm) free-standing Silicon Carbide (SiC), developed by SenSiC GmbH, membranes as in-line, minimally invasive beam position monitors*. These devices offer high lateral resolution and minimal beam perturbation, making them particularly suitable for synchrotron radiation applications. Preliminary beam tests were conducted at the NanoMAX beamline (MAX IV) using highly focused (<1 µm FWHM) soft X-ray beams. SiC devices with 4-quadrant layouts demonstrated clear beam detection capability, though limitations emerged at the quadrant interfaces due to charge collection losses and charge multiplication under high electric fields. These effects were further investigated using Sentaurus TCAD simulations, which highlighted the potential for optimized sensor geometries to mitigate such issues. Results from a related SiC membrane intensity monitor, tested at the PTB four-crystal monochromator beamline at BESSY II demonstrated compatibility with tender and hard X-rays**. This device features a 3 mm diameter membrane consisting of a 0.3 µm p⁺ layer, 1.5 µm n⁻ active region, and a 370 µm n⁺ substrate, with Al contacts. Transmission tests in the 1.75 - 10 keV range confirmed excellent transparency (up to 97.55%) and uniform photocurrent response under 8 keV raster scans. The measured photocurrent at zero bias was 0.586 nA with 86% charge collection efficiency. Together, these results highlight the promising role of sub-2 µm SiC membranes for high-precision, in-line monitoring of X-ray beams across a wide spectral range, with ongoing developments targeting even thinner devices for optimized performance in soft X-ray applications.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-wedc02
Citations
2
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
16.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sub-micron ultra thin SiC free standing membranes for soft X-rays beam monitoring

Massimo Camarda, Simone Finizio, G. Trovato, Kewin Desjardins et al.
2 citations
JACOW
Diamond and Carbon-based Materials Research
16.08
article

Sub-micron ultra thin SiC free standing membranes for soft X-rays beam monitoring

Massimo Camarda, Simone Finizio, G. Trovato, Kewin Desjardins, Niccolò La Rosa, Marie Andrae
article en
2 citations

Abstract

Conventional X-ray beam monitors, such as gold meshes and conductive diamond films, often suffer from significant drawbacks, as diffraction effects, non-uniform transparency, low signal levels, and poor spatial resolution, particularly when applied to soft and tender X-ray beams. To address these limitations, we explore the use of ultra-thin (<2 µm) free-standing Silicon Carbide (SiC), developed by SenSiC GmbH, membranes as in-line, minimally invasive beam position monitors*. These devices offer high lateral resolution and minimal beam perturbation, making them particularly suitable for synchrotron radiation applications. Preliminary beam tests were conducted at the NanoMAX beamline (MAX IV) using highly focused (<1 µm FWHM) soft X-ray beams. SiC devices with 4-quadrant layouts demonstrated clear beam detection capability, though limitations emerged at the quadrant interfaces due to charge collection losses and charge multiplication under high electric fields. These effects were further investigated using Sentaurus TCAD simulations, which highlighted the potential for optimized sensor geometries to mitigate such issues. Results from a related SiC membrane intensity monitor, tested at the PTB four-crystal monochromator beamline at BESSY II demonstrated compatibility with tender and hard X-rays**. This device features a 3 mm diameter membrane consisting of a 0.3 µm p⁺ layer, 1.5 µm n⁻ active region, and a 370 µm n⁺ substrate, with Al contacts. Transmission tests in the 1.75 - 10 keV range confirmed excellent transparency (up to 97.55%) and uniform photocurrent response under 8 keV raster scans. The measured photocurrent at zero bias was 0.586 nA with 86% charge collection efficiency. Together, these results highlight the promising role of sub-2 µm SiC membranes for high-precision, in-line monitoring of X-ray beams across a wide spectral range, with ongoing developments targeting even thinner devices for optimized performance in soft X-ray applications.

JACOW
Openalex Percentile: Top 3%
Diamond and Carbon-based Materials Research
16.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.