Less is more: downsampling x-ray images improves pose estimation accuracy

Biplanar videoradiography (BVR) is a gold-standard technique for quantifying<i>in vivo</i>bone motion, yet the influence of x-ray image resolution on pose estimation accuracy remains unexplored. This study investigates how downsampling x-ray images impacts model-based pose estimation, using high-speed BVR data from a participant with implanted tantalum beads. Images were downsampled from 2048 × 2048 to 512 × 512 using bicubic and nearest-neighbour interpolation. Across multiple bones and varying perturbation levels, downsampling significantly reduced rotational and translational errors when compared to full-resolution images for both interpolation results. Bicubic interpolation led to slightly improved pose accuracy for certain bones, demonstrating enhanced edge clarity that benefits the optimisation algorithm. Pose estimates for full-resolution images exhibited more outliers and greater variability for all the bones investigated. These findings highlight that downsampling images improves pose estimation accuracy even for challenging anatomical areas such as the ankle. We recommend bicubic downsampling to 512 × 512 pixels as a best practice for BVR tracking of the ankle complex, when using both automated optimisation and manual workflows.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-01-20
DOI
https://doi.org/10.1088/1873-4030/ae2909
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Less is more: downsampling x-ray images improves pose estimation accuracy

Michael J. Rainbow, Lauren Welte, David L. Williams, Dajung Yoon et al.
Medical Engineering & Physics
Total Knee Arthroplasty Outcomes
article

Less is more: downsampling x-ray images improves pose estimation accuracy

Michael J. Rainbow, Lauren Welte, David L. Williams, Dajung Yoon, Joseph J Criso
article en

Abstract

Biplanar videoradiography (BVR) is a gold-standard technique for quantifying<i>in vivo</i>bone motion, yet the influence of x-ray image resolution on pose estimation accuracy remains unexplored. This study investigates how downsampling x-ray images impacts model-based pose estimation, using high-speed BVR data from a participant with implanted tantalum beads. Images were downsampled from 2048 × 2048 to 512 × 512 using bicubic and nearest-neighbour interpolation. Across multiple bones and varying perturbation levels, downsampling significantly reduced rotational and translational errors when compared to full-resolution images for both interpolation results. Bicubic interpolation led to slightly improved pose accuracy for certain bones, demonstrating enhanced edge clarity that benefits the optimisation algorithm. Pose estimates for full-resolution images exhibited more outliers and greater variability for all the bones investigated. These findings highlight that downsampling images improves pose estimation accuracy even for challenging anatomical areas such as the ankle. We recommend bicubic downsampling to 512 × 512 pixels as a best practice for BVR tracking of the ankle complex, when using both automated optimisation and manual workflows.

Medical Engineering & PhysicsVol. 147(2)
University of Alberta (CA), Queen's University (CA), Brown University (US), Cardiff University (GB)
Openalex Percentile: Top 83%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.