Performance analysis of the LHC BSRL and possible improvements

The Beam Synchrotron Radiation Longitudinal density monitor (BSRL) at the LHC leverages time-correlated single-photon counting to provide high-dynamic-range measurements of the relative charges in each RF bucket with a time resolution of 50 ps. These measurements are needed for the operation of the LHC as well as for the luminosity calibration required by the LHC Experiments. In this work we identify sources of error for each the BSRL components. These components are the optics (mirrors, filters and optical fibres), the detector (a hybrid photomultiplier - HPM), the electronics (a Time to Digital Converter - TDC) and some data analysis used for the final results. Knowledge of the errors of the BSRL is crucially important as any errors are passed directly into the luminosity calibration of the LHC experiments. We quantify the errors introduced by each of these parts and for external systems, like the LHC timing. For the largest contributors to the overall error, we propose mitigation strategies that can be deployed in the short term.

Authors

Publication Details

Journal
CERN Document Server (European Organization for Nuclear Research)
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-modc02
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance analysis of the LHC BSRL and possible improvements

A. Schloegelhofer, D. Butti, Kieran Hanahoe, Miguel Martin Nieto et al.
CERN Document Server (European Organization for Nuclear Research)
Particle Detector Development and Performance
article

Performance analysis of the LHC BSRL and possible improvements

A. Schloegelhofer, D. Butti, Kieran Hanahoe, Miguel Martin Nieto, Manuel Gonzalez-Berges, Alex S. Hill, Hao Zhang, Stefano Mazzoni, Alexander Jury
article en

Abstract

The Beam Synchrotron Radiation Longitudinal density monitor (BSRL) at the LHC leverages time-correlated single-photon counting to provide high-dynamic-range measurements of the relative charges in each RF bucket with a time resolution of 50 ps. These measurements are needed for the operation of the LHC as well as for the luminosity calibration required by the LHC Experiments. In this work we identify sources of error for each the BSRL components. These components are the optics (mirrors, filters and optical fibres), the detector (a hybrid photomultiplier - HPM), the electronics (a Time to Digital Converter - TDC) and some data analysis used for the final results. Knowledge of the errors of the BSRL is crucially important as any errors are passed directly into the luminosity calibration of the LHC experiments. We quantify the errors introduced by each of these parts and for external systems, like the LHC timing. For the largest contributors to the overall error, we propose mitigation strategies that can be deployed in the short term.

CERN Document Server (European Organization for Nuclear Research)
Openalex Percentile: Top 79%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.