Influence of hydrogen evolution and corrosion on the bond strength of galvanized reinforcing steel in concrete with different binder types

The service life of reinforced concrete structures is often compromised by corrosion of the reinforcing steel, primarily due to carbonation and chloride ion diffusion, especially in marine environments. Zinc coating, particularly through hot-dip galvanizing, offers a cost-effective solution by enhancing resistance to chloride-induced corrosion. Galvanized steel requires higher chloride content to start corrosion and produces less expansive corrosion products than normal steel. Yet, zinc may corrode early in fresh concrete, releasing hydrogen and increasing porosity at the steel–concrete interface, potentially weakening bond strength. This study investigates the effects of corrosion products on the bond strength of galvanized steel in three concrete types: Portland composite cement (PCC), fly ash (FA), and calcined clay (CC) concrete. Electrochemical tests (potentiodynamic and linear polarization resistance), pull-out tests, and chemical analyses (XRF and SEM) were conducted. PCC was used as the reference binder, with FA and CC replacing 30% by weight of the total binder. Water-to-binder ratios of 0.4 and 0.6 were tested. Results showed that galvanized steel initially exhibited low open circuit potential (OCP) and hydrogen evolution, later stabilizing with a protective zinc compound layer. FA concrete demonstrated the highest bond strength due to superior compressive strength. Surprisingly, CC concrete, despite lower pH, exhibited higher corrosion resistance than PCC and FA due to limited oxygen diffusion from its dense structure and early strength development. However, hydrogen evolution in CC reduced the bond strength. Adding 2% chloride by weight led to high corrosion rates but increased bond strength due to corrosion product filling at the steel–concrete interface, benefiting both galvanized and bare steels. • Early OCP drop shows H 2 evolution; OCP rises as passive film forms on steel. • Galvanized steel had lower bond but improved later due to pore-filling corrosion. • Fly ash and calcined clay lower pH, but dense concrete structure limiting O 2 supply, reducing steel corrosion. • Calcined clay concrete reduces bond strength due to early H 2 evolution with galvanized steel.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2026-01-20
DOI
https://doi.org/10.1016/j.jobe.2026.115328
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of hydrogen evolution and corrosion on the bond strength of galvanized reinforcing steel in concrete with different binder types

Pakawat Sancharoen, Mengty Toeng, Somnuk Tangtermsirikul
Journal of Building Engineering
Concrete Corrosion and Durability
article

Influence of hydrogen evolution and corrosion on the bond strength of galvanized reinforcing steel in concrete with different binder types

Pakawat Sancharoen, Mengty Toeng, Somnuk Tangtermsirikul
article en

Abstract

The service life of reinforced concrete structures is often compromised by corrosion of the reinforcing steel, primarily due to carbonation and chloride ion diffusion, especially in marine environments. Zinc coating, particularly through hot-dip galvanizing, offers a cost-effective solution by enhancing resistance to chloride-induced corrosion. Galvanized steel requires higher chloride content to start corrosion and produces less expansive corrosion products than normal steel. Yet, zinc may corrode early in fresh concrete, releasing hydrogen and increasing porosity at the steel–concrete interface, potentially weakening bond strength. This study investigates the effects of corrosion products on the bond strength of galvanized steel in three concrete types: Portland composite cement (PCC), fly ash (FA), and calcined clay (CC) concrete. Electrochemical tests (potentiodynamic and linear polarization resistance), pull-out tests, and chemical analyses (XRF and SEM) were conducted. PCC was used as the reference binder, with FA and CC replacing 30% by weight of the total binder. Water-to-binder ratios of 0.4 and 0.6 were tested. Results showed that galvanized steel initially exhibited low open circuit potential (OCP) and hydrogen evolution, later stabilizing with a protective zinc compound layer. FA concrete demonstrated the highest bond strength due to superior compressive strength. Surprisingly, CC concrete, despite lower pH, exhibited higher corrosion resistance than PCC and FA due to limited oxygen diffusion from its dense structure and early strength development. However, hydrogen evolution in CC reduced the bond strength. Adding 2% chloride by weight led to high corrosion rates but increased bond strength due to corrosion product filling at the steel–concrete interface, benefiting both galvanized and bare steels. • Early OCP drop shows H 2 evolution; OCP rises as passive film forms on steel. • Galvanized steel had lower bond but improved later due to pore-filling corrosion. • Fly ash and calcined clay lower pH, but dense concrete structure limiting O 2 supply, reducing steel corrosion. • Calcined clay concrete reduces bond strength due to early H 2 evolution with galvanized steel.

Journal of Building EngineeringVol. 119
Thammasat University (TH)
Life below water
Openalex Percentile: Top 84%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.