Initial implementation of a new orbit feedback system using MicroTCA.4 for the PF user operations

A new orbit feedback system has been introduced to the PF-ring, a synchrotron radiation source at KEK, starting from the third operation period of FY2024. The new system is built with state-of-the-art digital signal processing circuits based on the MicroTCA.4 standard. The stored beam’s closed orbit distortion (COD) is measured at a 10 kHz rate using the circuits matched to the number of BPMs, and corrected to a designated reference orbit by feeding back the results of matrix calculations using the inverse response matrix to the currents of fast steering magnets. The transition from the legacy VME-based system, which had been in service for nearly 30 years, was carried out carefully and stepwise during the startup phase of the third operation period. The reference orbit was successfully transferred to the new system, and even in-vacuum undulators with a minimum gap of 4 mm were operated without requiring additional orbit corrections. In this presentation, we will describe the setup of the newly implemented system, the transition process from the old system, and plans for future improvements.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-tupmo25
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial implementation of a new orbit feedback system using MicroTCA.4 for the PF user operations

Mami Shiozawa, Yong Ho Chin, Hidenori Sagehashi, Mikoto Tadano et al.
JACOW
Particle Accelerators and Free-Electron Lasers
article

Initial implementation of a new orbit feedback system using MicroTCA.4 for the PF user operations

Mami Shiozawa, Yong Ho Chin, Hidenori Sagehashi, Mikoto Tadano, Ryota Takai
article en

Abstract

A new orbit feedback system has been introduced to the PF-ring, a synchrotron radiation source at KEK, starting from the third operation period of FY2024. The new system is built with state-of-the-art digital signal processing circuits based on the MicroTCA.4 standard. The stored beam’s closed orbit distortion (COD) is measured at a 10 kHz rate using the circuits matched to the number of BPMs, and corrected to a designated reference orbit by feeding back the results of matrix calculations using the inverse response matrix to the currents of fast steering magnets. The transition from the legacy VME-based system, which had been in service for nearly 30 years, was carried out carefully and stepwise during the startup phase of the third operation period. The reference orbit was successfully transferred to the new system, and even in-vacuum undulators with a minimum gap of 4 mm were operated without requiring additional orbit corrections. In this presentation, we will describe the setup of the newly implemented system, the transition process from the old system, and plans for future improvements.

JACOW
Openalex Percentile: Top 83%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.