Current status of developing pepper-pot emittance monitor for high-intensity ion beam

The experiment to measure the Electric Dipole Moment (EDM) of Francium (Fr) is in progress by Center for Nuclear Study (CNS), UTokyo. Fr is produced via a nuclear fusion reaction by bombarding a gold target with oxygen-18 beam, requiring a beam intensity of 18 eμA or higher. However, the transport efficiency of the current beam line decreases to 66 % when the beam intensity exceeds 10 eμA. To address this issue, we are developing a pepper-pot emittance monitor (PEM) optimized for high-intensity beams. The improvements include locating the camera far from the beam line to minimize radiation damage, achieving a distance 4.1 m while maintaining the position error of 0.13 mm. Additionally, we conducted beam tests to verify measurement errors and found the results were consistent with the measurement errors estimated from the PEM structure. Furthermore, the beam shutter time 0.27 was estimated to be acceptable up to the beam power 1000 W to prevent PEM overheating.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-tupmo19
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Current status of developing pepper-pot emittance monitor for high-intensity ion beam

Y. Sakemi, Yasuteru Kotaka, Hiroyuki Matsuzaki, Keita Kamakura et al.
JACOW
Particle accelerators and beam dynamics
article

Current status of developing pepper-pot emittance monitor for high-intensity ion beam

Y. Sakemi, Yasuteru Kotaka, Hiroyuki Matsuzaki, Keita Kamakura, Jun-Ichi Ohnishi
article en

Abstract

The experiment to measure the Electric Dipole Moment (EDM) of Francium (Fr) is in progress by Center for Nuclear Study (CNS), UTokyo. Fr is produced via a nuclear fusion reaction by bombarding a gold target with oxygen-18 beam, requiring a beam intensity of 18 eμA or higher. However, the transport efficiency of the current beam line decreases to 66 % when the beam intensity exceeds 10 eμA. To address this issue, we are developing a pepper-pot emittance monitor (PEM) optimized for high-intensity beams. The improvements include locating the camera far from the beam line to minimize radiation damage, achieving a distance 4.1 m while maintaining the position error of 0.13 mm. Additionally, we conducted beam tests to verify measurement errors and found the results were consistent with the measurement errors estimated from the PEM structure. Furthermore, the beam shutter time 0.27 was estimated to be acceptable up to the beam power 1000 W to prevent PEM overheating.

JACOW
Openalex Percentile: Top 85%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.