Laser transport and stabilization for the CSNS laser wire profile monitor prototype

A laser wire monitor has bean developed at the China Spallation Neutron Source (CSNS).The monitor utilizes a 1064 nm laser source to measure the horizontal and vertical profiles of a negative hydrogen ion (H-) beam with an energy of 80 MeV in the injection zone. This paper describes the design of the laser optical path layout and the characterization of the transport performance. The experiment focuses on the laser system's quality factor M2 of the laser after more than 60 meters of transmission as well as the beam pointing stability. In this experiment, the laser quality factor M2 after transmission is better than 4, and the beam pointing stability after focusing is less than ± 2.5 um, which is able to satisfy the required specifications for the first laser wire monitor of the CSNS.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-tupco38
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser transport and stabilization for the CSNS laser wire profile monitor prototype

Renhong Liu, B Zhang, Zhihong Xu, Renjun Yang et al.
JACOW
Particle accelerators and beam dynamics
article

Laser transport and stabilization for the CSNS laser wire profile monitor prototype

Renhong Liu, B Zhang, Zhihong Xu, Renjun Yang, Cheming Chen, Pengji Ding, sijie yan
article en

Abstract

A laser wire monitor has bean developed at the China Spallation Neutron Source (CSNS).The monitor utilizes a 1064 nm laser source to measure the horizontal and vertical profiles of a negative hydrogen ion (H-) beam with an energy of 80 MeV in the injection zone. This paper describes the design of the laser optical path layout and the characterization of the transport performance. The experiment focuses on the laser system's quality factor M2 of the laser after more than 60 meters of transmission as well as the beam pointing stability. In this experiment, the laser quality factor M2 after transmission is better than 4, and the beam pointing stability after focusing is less than ± 2.5 um, which is able to satisfy the required specifications for the first laser wire monitor of the CSNS.

JACOW
Affordable and clean energy
Openalex Percentile: Top 85%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.