Fast Corrector Vessel Selection for High Bandwidth Fast Orbit Feedback

The Diamond-II upgrade will enhance the performance of the Diamond Light Source synchrotron, including improved beam stability by the Fast Orbit Feedback system. Achieving the targeted closed-loop bandwidth of 1 kHz necessitates an open-loop actuator bandwidth of approximately 10 kHz, which presents significant design challenges for the corrector magnet vacuum vessel. Additionally, subsystems such as the corrector magnet power supplies and Beam Position Monitors, must comply with a stringent closed-loop latency of less than 100 microseconds. Initially, a 1 millimetre stainless steel vessel was deemed viable; however, experimental findings indicated that the combination of stainless steel and neighbouring copper vessels resulted in a decrease in both integrated magnetic field strength and system bandwidth. This prompted a reassessment of the material selection for the fast corrector vessels to optimise orbit feedback performance. This paper investigates these challenges, analyses experimental data, and explores solutions to achieve the necessary bandwidth for the Diamond-II upgrade.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-tupco15
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Corrector Vessel Selection for High Bandwidth Fast Orbit Feedback

Shohan Banerjee, V. Bleko, Filip Malinowski
JACOW
Particle Accelerators and Free-Electron Lasers
article

Fast Corrector Vessel Selection for High Bandwidth Fast Orbit Feedback

Shohan Banerjee, V. Bleko, Filip Malinowski
article en

Abstract

The Diamond-II upgrade will enhance the performance of the Diamond Light Source synchrotron, including improved beam stability by the Fast Orbit Feedback system. Achieving the targeted closed-loop bandwidth of 1 kHz necessitates an open-loop actuator bandwidth of approximately 10 kHz, which presents significant design challenges for the corrector magnet vacuum vessel. Additionally, subsystems such as the corrector magnet power supplies and Beam Position Monitors, must comply with a stringent closed-loop latency of less than 100 microseconds. Initially, a 1 millimetre stainless steel vessel was deemed viable; however, experimental findings indicated that the combination of stainless steel and neighbouring copper vessels resulted in a decrease in both integrated magnetic field strength and system bandwidth. This prompted a reassessment of the material selection for the fast corrector vessels to optimise orbit feedback performance. This paper investigates these challenges, analyses experimental data, and explores solutions to achieve the necessary bandwidth for the Diamond-II upgrade.

JACOW
Openalex Percentile: Top 83%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fast Corrector Vessel Selection for High Bandwidth Fast Orbit Feedback — Shohan Banerjee, V. Bleko, et al. · JACOW (2026) | TGRS Research Map | TGRS