Isolating the light of a single bunch: determining the viability of operating vertical-plane Pulse Picking by Resonant Excitation at Diamond-II to serve timing mode users

Pulse Picking by Resonant Excitation (PPRE) enables synchrotron facilities to provide single-bunch light for timing users without interrupting multi-bunch operation*. We report the first vertical-plane PPRE tests at Diamond using the Multi-Bunch Feedback system, achieving vertical bunch-size growth and measurable X-ray enlargement. A simple novel optimisation improved PPRE purity by reducing the baseline emittance. Beyond readily-available diagnostics, we demonstrate how crystallographic diffraction can be used as a user-relevant method to characterise PPRE with statistically significant evidence of isolating a single excited bunch. Together, these methods provide a practical and user-orientated framework for synchrotron facilities considering similar timing-mode capabilities.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-tubc01
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Isolating the light of a single bunch: determining the viability of operating vertical-plane Pulse Picking by Resonant Excitation at Diamond-II to serve timing mode users

Mark R. Warren, Ben A. Coulson, Γαβριήλ Καρράς, Seb Wilkes et al.
JACOW
Particle Accelerators and Free-Electron Lasers
article

Isolating the light of a single bunch: determining the viability of operating vertical-plane Pulse Picking by Resonant Excitation at Diamond-II to serve timing mode users

Mark R. Warren, Ben A. Coulson, Γαβριήλ Καρράς, Seb Wilkes, V. Bleko, Philip Burrows, Alun Morgan
article en

Abstract

Pulse Picking by Resonant Excitation (PPRE) enables synchrotron facilities to provide single-bunch light for timing users without interrupting multi-bunch operation*. We report the first vertical-plane PPRE tests at Diamond using the Multi-Bunch Feedback system, achieving vertical bunch-size growth and measurable X-ray enlargement. A simple novel optimisation improved PPRE purity by reducing the baseline emittance. Beyond readily-available diagnostics, we demonstrate how crystallographic diffraction can be used as a user-relevant method to characterise PPRE with statistically significant evidence of isolating a single excited bunch. Together, these methods provide a practical and user-orientated framework for synchrotron facilities considering similar timing-mode capabilities.

JACOW
Reduced inequalities
Openalex Percentile: Top 83%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.