Bioelectronic VertiTFET with Multilayer Nanosheet Gating for Dual-Mode, Ultra-Sensitive Stroke State Profiling

This study investigates a rapid, cost-effective method for brain stroke detection using a Recessed Drain (RD) Heterojunction (HJ) Vertically Stacked (VS), Gate-All-Around (GAA), and Nanosheet (NS) Tunneling Field-Effect Transistor (TFET) biosensor. The core innovation lies in the three vertically stacked Silicon nanosheet channels, which provide an expanded sensing surface, enhanced electrostatic control, and improved biomolecule interaction compared to single-channel devices. The proposed RD-HJ-VS-GAA-NS-TFET outperforms conventional biosensor architectures such as planar MOSFETs, multigate FETs, and nanowire FETs, due to its wider channel and multilayered design. To address strain effects arising from silicon growth on SiGe, a comparative analysis between conventional silicon and strained silicon nanosheet channels is explicitly performed. The sensitivity analysis is carried out by examining key parameters, including the Drain Current (<i>I</i><sub>D</sub>) response, Subthreshold Swing behavior (SS), and the switching ratio (<i>I</i><sub>ON</sub>/<i>I</i><sub>OFF</sub>). The dielectric constant exhibits significant variation between healthy and stroke-affected brain tissues due to the distinct electromagnetic properties of brain tissues, particularly when they interact with nanocavities at high frequencies. Device performance is analyzed with respect to cavity length, cavity thickness, gate work function configurations, cavity orientation, filling factor, and nonuniform step profiles. The <i>I</i><sub>ON</sub>/<i>I</i><sub>OFF</sub> ratio increases from 3.58 × 10<sup>11</sup> under hemorrhagic state (<i>k</i> = 30) to 5.40 × 10<sup>11</sup> under healthy state (<i>k</i> = 42) and further to 1.05 × 10<sup>12</sup> under ischemic state (<i>k</i> = 61), highlighting the improved switching characteristics of the proposed biosensor, which is crucial for effectively distinguishing between stroke-affected and healthy brain tissues. The proposed RD-HJ-VS-GAA-NS-TFET biosensor shows strong potential as a label-free, Point-Of-Care (POC) diagnostic platform for rapid and accurate stroke detection.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2026-01-20
DOI
https://doi.org/10.1021/acsabm.5c01850
Primary Topic
Advancements in Semiconductor Devices and Circuit Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bioelectronic VertiTFET with Multilayer Nanosheet Gating for Dual-Mode, Ultra-Sensitive Stroke State Profiling

Lakshmi Priya G, Poorna Sundari M
ACS Applied Bio Materials
Advancements in Semiconductor Devices and Circuit Design
article

Bioelectronic VertiTFET with Multilayer Nanosheet Gating for Dual-Mode, Ultra-Sensitive Stroke State Profiling

Lakshmi Priya G, Poorna Sundari M
article en

Abstract

This study investigates a rapid, cost-effective method for brain stroke detection using a Recessed Drain (RD) Heterojunction (HJ) Vertically Stacked (VS), Gate-All-Around (GAA), and Nanosheet (NS) Tunneling Field-Effect Transistor (TFET) biosensor. The core innovation lies in the three vertically stacked Silicon nanosheet channels, which provide an expanded sensing surface, enhanced electrostatic control, and improved biomolecule interaction compared to single-channel devices. The proposed RD-HJ-VS-GAA-NS-TFET outperforms conventional biosensor architectures such as planar MOSFETs, multigate FETs, and nanowire FETs, due to its wider channel and multilayered design. To address strain effects arising from silicon growth on SiGe, a comparative analysis between conventional silicon and strained silicon nanosheet channels is explicitly performed. The sensitivity analysis is carried out by examining key parameters, including the Drain Current (<i>I</i><sub>D</sub>) response, Subthreshold Swing behavior (SS), and the switching ratio (<i>I</i><sub>ON</sub>/<i>I</i><sub>OFF</sub>). The dielectric constant exhibits significant variation between healthy and stroke-affected brain tissues due to the distinct electromagnetic properties of brain tissues, particularly when they interact with nanocavities at high frequencies. Device performance is analyzed with respect to cavity length, cavity thickness, gate work function configurations, cavity orientation, filling factor, and nonuniform step profiles. The <i>I</i><sub>ON</sub>/<i>I</i><sub>OFF</sub> ratio increases from 3.58 × 10<sup>11</sup> under hemorrhagic state (<i>k</i> = 30) to 5.40 × 10<sup>11</sup> under healthy state (<i>k</i> = 42) and further to 1.05 × 10<sup>12</sup> under ischemic state (<i>k</i> = 61), highlighting the improved switching characteristics of the proposed biosensor, which is crucial for effectively distinguishing between stroke-affected and healthy brain tissues. The proposed RD-HJ-VS-GAA-NS-TFET biosensor shows strong potential as a label-free, Point-Of-Care (POC) diagnostic platform for rapid and accurate stroke detection.

ACS Applied Bio MaterialsVol. 9(3)
Advanced Materials and Technologies (Slovenia) (SI), Vellore Institute of Technology University (IN)
Industry, innovation and infrastructure
Openalex Percentile: Top 83%
Advancements in Semiconductor Devices and Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.