First measurements of a prototype stripline BPM for PETRA IV comparison with simulation

We present signal and thermal measurements from the first prototype of a stripline Beam Position Monitor (BPM) intended for the PETRA IV synchrotron ring [1]. The monitor was installed at the PETRA III testbed for evaluation and compared against CST Studio Suite [2] simulation results. Initial measurements revealed unexpected signal oscillations and significant heating (up to 135 °C), which were not reproduced in ideal models. For a smooth beam pipe, the expected power loss based on the wake-loss factor would only be 5 W. Including mechanical details such as flanges and copper gaskets in the simulation revealed cavity-induced resonances, which increased the power loss up to 96 W. The updated model showed good agreement with the measured signals in both time (TD) and frequency domains (FD) as well as with thermal data. Replacing the gasket with a RF-sealing variant lowered the measured temperature to 65 °C. This study highlights that multiple mechanical and electromagnetic factors must be understood and included in simulations to predict beam-induced effects in high-frequency diagnostics accurately.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-wepco26
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First measurements of a prototype stripline BPM for PETRA IV comparison with simulation

P. N. Swallow, Martin Lantschner, Dirk Lipka, Gero Kube
JACOW
Particle Accelerators and Free-Electron Lasers
article

First measurements of a prototype stripline BPM for PETRA IV comparison with simulation

P. N. Swallow, Martin Lantschner, Dirk Lipka, Gero Kube
article en

Abstract

We present signal and thermal measurements from the first prototype of a stripline Beam Position Monitor (BPM) intended for the PETRA IV synchrotron ring [1]. The monitor was installed at the PETRA III testbed for evaluation and compared against CST Studio Suite [2] simulation results. Initial measurements revealed unexpected signal oscillations and significant heating (up to 135 °C), which were not reproduced in ideal models. For a smooth beam pipe, the expected power loss based on the wake-loss factor would only be 5 W. Including mechanical details such as flanges and copper gaskets in the simulation revealed cavity-induced resonances, which increased the power loss up to 96 W. The updated model showed good agreement with the measured signals in both time (TD) and frequency domains (FD) as well as with thermal data. Replacing the gasket with a RF-sealing variant lowered the measured temperature to 65 °C. This study highlights that multiple mechanical and electromagnetic factors must be understood and included in simulations to predict beam-induced effects in high-frequency diagnostics accurately.

JACOW
Affordable and clean energy
Openalex Percentile: Top 83%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

First measurements of a prototype stripline BPM for PETRA IV comparison with simulation — P. N. Swallow, Martin Lantschner, et al. · JACOW (2026) | TGRS Research Map | TGRS