Three-Chamber Images Are More Useful than Four-Chamber Images for the Volumetric Method of Degenerative Mitral Regurgitation

<b>Background/Objectives:</b> Effective regurgitant orifice area (EROA) is a critical parameter in assessing mitral regurgitation (MR) severity. The Japanese Circulation Society recommends a volumetric method which uses mitral annular diameters from apical four-chamber (A4C) and two-chamber (A2C) views. However, given the elliptical shape of the mitral annulus, use of apical long-axis (A3C) and A2C views, which reflect the anatomical long and short axes, may improve measurement accuracy. This study aimed to determine the optimal echocardiographic view combination for precise EROA quantification in degenerative MR (DMR). <b>Methods:</b> We retrospectively analyzed 98 patients with DMR who underwent both transthoracic echocardiography (TTE) and three-dimensional transesophageal echocardiography (3D TEE) within three months between April 2018 and December 2023. EROA was calculated using volumetric methods based on two TTE view combinations, A4C-A2C (EROA 4/2) and A3C-A2C (EROA 3/2). These were compared with 3D TEE-derived vena contracta area (VCA), which served as reference standard. <b>Results:</b> Mean values of EROA were 0.57 ± 0.23 cm<sup>2</sup> for EROA 4/2, 0.50 ± 0.21 cm<sup>2</sup> for EROA 3/2, and 0.49 ± 0.18 cm<sup>2</sup> for 3D TEE VCA. EROA 4/2 was significantly larger than VCA (<i>p</i> < 0.01), whereas EROA 3/2 did not significantly differ from VCA (<i>p</i> = 0.41) and showed a stronger correlation with VCA than EROA 4/2 (r = 0.829 vs. r = 0.638, <i>p</i> < 0.01). <b>Conclusions:</b> Volumetric EROA assessment using A3C and A2C views provides more accurate quantification in DMR than the conventional A4C and A2C approach. Anatomically appropriate imaging planes should be prioritized to enhance the accuracy of MR severity evaluation.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-19
DOI
https://doi.org/10.3390/jcm15020807
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-Chamber Images Are More Useful than Four-Chamber Images for the Volumetric Method of Degenerative Mitral Regurgitation

Haruto Matsumoto, Noriko Suzuki-Eguchi, Shuhei Aoki, Kenji Kawasaki et al.
Journal of Clinical Medicine
Cardiac Valve Diseases and Treatments
article

Three-Chamber Images Are More Useful than Four-Chamber Images for the Volumetric Method of Degenerative Mitral Regurgitation

Haruto Matsumoto, Noriko Suzuki-Eguchi, Shuhei Aoki, Kenji Kawasaki, Makiko Kinoshita, Kazuyuki Matsushita, Y. Noguchi, Hiroyuki Takaoka, Yoshio Kobayashi, Ami Tateyama-Niwano, Haruka Sasaki, Kazuki Yoshida, Katsuya Suzuki
article en

Abstract

<b>Background/Objectives:</b> Effective regurgitant orifice area (EROA) is a critical parameter in assessing mitral regurgitation (MR) severity. The Japanese Circulation Society recommends a volumetric method which uses mitral annular diameters from apical four-chamber (A4C) and two-chamber (A2C) views. However, given the elliptical shape of the mitral annulus, use of apical long-axis (A3C) and A2C views, which reflect the anatomical long and short axes, may improve measurement accuracy. This study aimed to determine the optimal echocardiographic view combination for precise EROA quantification in degenerative MR (DMR). <b>Methods:</b> We retrospectively analyzed 98 patients with DMR who underwent both transthoracic echocardiography (TTE) and three-dimensional transesophageal echocardiography (3D TEE) within three months between April 2018 and December 2023. EROA was calculated using volumetric methods based on two TTE view combinations, A4C-A2C (EROA 4/2) and A3C-A2C (EROA 3/2). These were compared with 3D TEE-derived vena contracta area (VCA), which served as reference standard. <b>Results:</b> Mean values of EROA were 0.57 ± 0.23 cm<sup>2</sup> for EROA 4/2, 0.50 ± 0.21 cm<sup>2</sup> for EROA 3/2, and 0.49 ± 0.18 cm<sup>2</sup> for 3D TEE VCA. EROA 4/2 was significantly larger than VCA (<i>p</i> < 0.01), whereas EROA 3/2 did not significantly differ from VCA (<i>p</i> = 0.41) and showed a stronger correlation with VCA than EROA 4/2 (r = 0.829 vs. r = 0.638, <i>p</i> < 0.01). <b>Conclusions:</b> Volumetric EROA assessment using A3C and A2C views provides more accurate quantification in DMR than the conventional A4C and A2C approach. Anatomically appropriate imaging planes should be prioritized to enhance the accuracy of MR severity evaluation.

Journal of Clinical MedicineVol. 15(2)
Chiba University (JP), Chiba University Hospital (JP)
Chiba University, Japan Society for the Promotion of Science
Openalex Percentile: Top 84%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.