Clinical validation of a multisensor wearable device (SOUNDI) for the diagnosis of obstructive sleep apnea (OSA)

Obstructive sleep apnea (OSA) is a common disorder with significant health and economic burdens and the current standard of diagnosis is performed through polysomnography. This study assesed the diagnostic accuracy of SOUNDI, a novel wearable device that uses optical, acoustical, and accelerometer signals for home sleep testing. Fifty patients suspected of having OSA underwent simultaneous monitoring with standard Type 3 cardiorespiratory monitoring (PG) and SOUNDI system. The apnea‒hypopnea index (AHI), oxygen desaturation index and oxygen saturation parameters derived from SOUNDI were highly correlated (r = 0.87-0.99, p < 0.0001) and were in good agreement with the PG. SOUNDI study was shown to have excellent specificity and positive predictive value (PPV) at various AHI values ( AHI ≥ 5/h: specificity = 0.769, PPV = 0.919; AHI ≥ 15/h: specificity = 0.852, PPV = 0.833; AHI ≥ 30/h: specificity = 0.833, PPV = 0.100). Patient feedback highlighted significant satisfaction with the wearingability and ease of use of the SOUNDI, indicating a preference for multi-night monitoring. The findings suggest that the SOUNDI offers a patient-centric and potentially cost-effective alternative to PG for OSA diagnosis in the home setting.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-20
DOI
https://doi.org/10.1038/s41598-026-36290-y
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical validation of a multisensor wearable device (SOUNDI) for the diagnosis of obstructive sleep apnea (OSA)

Dario Bovio, Caterina Salito, Carolina Lombardi
Scientific Reports
Obstructive Sleep Apnea Research
article

Clinical validation of a multisensor wearable device (SOUNDI) for the diagnosis of obstructive sleep apnea (OSA)

Dario Bovio, Caterina Salito, Carolina Lombardi
article en

Abstract

Obstructive sleep apnea (OSA) is a common disorder with significant health and economic burdens and the current standard of diagnosis is performed through polysomnography. This study assesed the diagnostic accuracy of SOUNDI, a novel wearable device that uses optical, acoustical, and accelerometer signals for home sleep testing. Fifty patients suspected of having OSA underwent simultaneous monitoring with standard Type 3 cardiorespiratory monitoring (PG) and SOUNDI system. The apnea‒hypopnea index (AHI), oxygen desaturation index and oxygen saturation parameters derived from SOUNDI were highly correlated (r = 0.87-0.99, p < 0.0001) and were in good agreement with the PG. SOUNDI study was shown to have excellent specificity and positive predictive value (PPV) at various AHI values ( AHI ≥ 5/h: specificity = 0.769, PPV = 0.919; AHI ≥ 15/h: specificity = 0.852, PPV = 0.833; AHI ≥ 30/h: specificity = 0.833, PPV = 0.100). Patient feedback highlighted significant satisfaction with the wearingability and ease of use of the SOUNDI, indicating a preference for multi-night monitoring. The findings suggest that the SOUNDI offers a patient-centric and potentially cost-effective alternative to PG for OSA diagnosis in the home setting.

Scientific ReportsVol. 16(1)
Magna Graecia University (IT), IRCCS Istituto Auxologico Italiano (IT), Politecnico di Milano (IT)
Regione Lombardia, European Regional Development Fund
Openalex Percentile: Top 85%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.