Cost‐Effective and User‐Friendly Pencil Graphite Electrode Immunosensor for Label‐Free Detection of Carcinoembryonic Antigen

We present a novel, cost-effective sensor for carcinoembryonic antigen (CEA) detection utilizing a pencil graphite electrode (PGE) in combination with electrochemical impedance spectroscopy (EIS), which offers high sensitivity and selectivity. Anti-CEA/AuNPs/PGE was successfully illustrated as a label-free impedimetric immunosensor for the detection of CEA. Through EIS, we observed distinct impedance changes upon CEA binding, enabling real-time detection with high reproducibility and low interference from non-target molecules. Due to its satisfying impedimetric response, this new immunosensor demonstrated that it can be used for high-performance detection of CEA with a wide linear range extending from 13.2 to 1 × 10<sup>5</sup> pg mL<sup>-1</sup>, with correlation coefficients (R<sup>2</sup>) of 0.9923. The PGE's excellent conductive properties and surface stability allowed for the successful detection of CEA at low concentrations, demonstrating a detection limit of 4.4 pg mL<sup>-1</sup>, which is competitive with existing, more costly alternatives. The sensor's robust performance in spiked artificial urine samples indicates its potential for practical application in point-of-care cancer diagnostics, especially in resource-limited environments. The developed electrochemical biosensor holds promise for accurately detecting CEA in urine samples, offering a precise technique that could find valuable application in clinical tumor detection.

Authors

Institutions

Publication Details

Journal
Biotechnology and Applied Biochemistry
Published
2026-01-19
DOI
https://doi.org/10.1002/bab.70132
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cost‐Effective and User‐Friendly Pencil Graphite Electrode Immunosensor for Label‐Free Detection of Carcinoembryonic Antigen

Hüseyin Çelikkan, Sevda Akay Sazaklioglu
Biotechnology and Applied Biochemistry
Advanced biosensing and bioanalysis techniques
article

Cost‐Effective and User‐Friendly Pencil Graphite Electrode Immunosensor for Label‐Free Detection of Carcinoembryonic Antigen

Hüseyin Çelikkan, Sevda Akay Sazaklioglu
article en

Abstract

We present a novel, cost-effective sensor for carcinoembryonic antigen (CEA) detection utilizing a pencil graphite electrode (PGE) in combination with electrochemical impedance spectroscopy (EIS), which offers high sensitivity and selectivity. Anti-CEA/AuNPs/PGE was successfully illustrated as a label-free impedimetric immunosensor for the detection of CEA. Through EIS, we observed distinct impedance changes upon CEA binding, enabling real-time detection with high reproducibility and low interference from non-target molecules. Due to its satisfying impedimetric response, this new immunosensor demonstrated that it can be used for high-performance detection of CEA with a wide linear range extending from 13.2 to 1 × 10<sup>5</sup> pg mL<sup>-1</sup>, with correlation coefficients (R<sup>2</sup>) of 0.9923. The PGE's excellent conductive properties and surface stability allowed for the successful detection of CEA at low concentrations, demonstrating a detection limit of 4.4 pg mL<sup>-1</sup>, which is competitive with existing, more costly alternatives. The sensor's robust performance in spiked artificial urine samples indicates its potential for practical application in point-of-care cancer diagnostics, especially in resource-limited environments. The developed electrochemical biosensor holds promise for accurately detecting CEA in urine samples, offering a precise technique that could find valuable application in clinical tumor detection.

Biotechnology and Applied Biochemistry
Ankara University (TR), Gazi University (TR)
Gazi Üniversitesi
Openalex Percentile: Top 84%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.