Optimization of beam intensity measurement system of HIPA at PSI

Beam intensity measurement of high intensity proton accelerator at PSI mainly consists of several passive cavity type monitors and corresponding electronics. New VME based electronics are running in parallel for final online testing with the old CAMAC ones, which will be replaced soon. The new pre-amplifier of the VME system is suffering significant temperature-dependent drift, leading to an inaccurate measurement. Further, wrong transmission rate may lead to unexpected interlock and beam losses during operation. To address this issue many temperature compensation schemes were considered, numerous lab tests were conducted, eventually reach a temperature stabilization solution. Experimental validation demonstrates a factor of 4 reduction in temperature-induced measurement variance compared to previous implementation, achieving a temperature coefficient 166 ppm/degree for RF test signal. Furthermore, the new electronics incorporate a phase measurement of the 50.6 MHz proton bunches for beam energy monitoring. Beam tests show energy measurement consistency within ±0.15%. This implementation greatly facilitates the commissioning and status monitoring of the accelerator.

Authors

Publication Details

Journal
JACOW
Published
2026-01-20
DOI
https://doi.org/10.18429/jacow-ibic2025-mopmo12
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of beam intensity measurement system of HIPA at PSI

Pascal Huber, Jilei Sun, Pierre-André Duperrex, Waldemar Koprek
JACOW
Particle accelerators and beam dynamics
article

Optimization of beam intensity measurement system of HIPA at PSI

Pascal Huber, Jilei Sun, Pierre-André Duperrex, Waldemar Koprek
article en

Abstract

Beam intensity measurement of high intensity proton accelerator at PSI mainly consists of several passive cavity type monitors and corresponding electronics. New VME based electronics are running in parallel for final online testing with the old CAMAC ones, which will be replaced soon. The new pre-amplifier of the VME system is suffering significant temperature-dependent drift, leading to an inaccurate measurement. Further, wrong transmission rate may lead to unexpected interlock and beam losses during operation. To address this issue many temperature compensation schemes were considered, numerous lab tests were conducted, eventually reach a temperature stabilization solution. Experimental validation demonstrates a factor of 4 reduction in temperature-induced measurement variance compared to previous implementation, achieving a temperature coefficient 166 ppm/degree for RF test signal. Furthermore, the new electronics incorporate a phase measurement of the 50.6 MHz proton bunches for beam energy monitoring. Beam tests show energy measurement consistency within ±0.15%. This implementation greatly facilitates the commissioning and status monitoring of the accelerator.

JACOW
Affordable and clean energy
Openalex Percentile: Top 86%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of beam intensity measurement system of HIPA at PSI — Pascal Huber, Jilei Sun, et al. · JACOW (2026) | TGRS Research Map | TGRS