A Novel Concept and 3D Coupler for Robotic Correction of Spinal Deformities: In Vitro Experimental Testing

<sec><title>Background</title> Current techniques for surgical correction of spinal deformities impart realigning the deviated vertebrae along a rigid rod. Solid rods are a major restricting factor to vertebral manipulation, leading to incomplete, imprecise, and less predictable 3-dimensional (3D) correction. Additionally, forceful manual nonquantifiable maneuvers may result in potential implant failures and increased incidence of complications. We are introducing a machine-operated device for digitized segmental 6 degrees of freedom (6 DOF) correction of individual vertebral deviations. </sec><sec><title>Methods</title> We manufactured a 3D coupler incorporating multiple self-locking uniaxial joints. The device’s precision was tested by comparing targeted vs delivered motions. For functionality testing, we used computed tomography-based 3D-printed vertebral models to verify the device’s ability to manipulate the vertebra in each direction of motion. </sec><sec><title>Results</title> In all tested motions, the coupler accurately and repeatedly delivered the predicted targeted motions. The device could mobilize 2 vertebral models relative to each other in 4 out of 6 DOF. </sec><sec><title>Conclusions</title> The novel 3D coupler can deliver machine-driven, precise, and predictable multiplanar motion; it could manipulate the vertebral model in rotation and translation. </sec><sec><title>Clinical Relevance</title> The novel device addresses a crucial unmet need in spinal surgery by offering digital precision, true 6 DOF correction, and supporting robotic execution of surgical actions. </sec><sec><title>Level of Evidence</title> 5. </sec>

Authors

Institutions

Publication Details

Journal
The International Journal of Spine Surgery
Published
2026-01-20
DOI
https://doi.org/10.14444/8845
Primary Topic
Scoliosis diagnosis and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Concept and 3D Coupler for Robotic Correction of Spinal Deformities: In Vitro Experimental Testing

Robert K. Eastlack, PhD Darryl D’Lima, Behrooz A. Akbarnia, Youssef H. Elsebaie et al.
The International Journal of Spine Surgery
Scoliosis diagnosis and treatment
article

A Novel Concept and 3D Coupler for Robotic Correction of Spinal Deformities: In Vitro Experimental Testing

Robert K. Eastlack, PhD Darryl D’Lima, Behrooz A. Akbarnia, Youssef H. Elsebaie, Ron El-Hawary, Gregory M. Mundis, Hazem B. Elsebaie
article en

Abstract

<sec><title>Background</title> Current techniques for surgical correction of spinal deformities impart realigning the deviated vertebrae along a rigid rod. Solid rods are a major restricting factor to vertebral manipulation, leading to incomplete, imprecise, and less predictable 3-dimensional (3D) correction. Additionally, forceful manual nonquantifiable maneuvers may result in potential implant failures and increased incidence of complications. We are introducing a machine-operated device for digitized segmental 6 degrees of freedom (6 DOF) correction of individual vertebral deviations. </sec><sec><title>Methods</title> We manufactured a 3D coupler incorporating multiple self-locking uniaxial joints. The device’s precision was tested by comparing targeted vs delivered motions. For functionality testing, we used computed tomography-based 3D-printed vertebral models to verify the device’s ability to manipulate the vertebra in each direction of motion. </sec><sec><title>Results</title> In all tested motions, the coupler accurately and repeatedly delivered the predicted targeted motions. The device could mobilize 2 vertebral models relative to each other in 4 out of 6 DOF. </sec><sec><title>Conclusions</title> The novel 3D coupler can deliver machine-driven, precise, and predictable multiplanar motion; it could manipulate the vertebral model in rotation and translation. </sec><sec><title>Clinical Relevance</title> The novel device addresses a crucial unmet need in spinal surgery by offering digital precision, true 6 DOF correction, and supporting robotic execution of surgical actions. </sec><sec><title>Level of Evidence</title> 5. </sec>

The International Journal of Spine Surgery
Boston Children's Hospital (US), Scripps Health (US), San Diego Spine Institute (US), Scripps Clinic (US)
Openalex Percentile: Top 84%
Scoliosis diagnosis and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Concept and 3D Coupler for Robotic Correction of Spinal Deformities: In Vitro Experimental Testing — Robert K. Eastlack, PhD Darryl D’Lima, et al. · The International Journal of Spine Surgery (2026) | TGRS Research Map | TGRS