How reliable are estimates of trace contaminants in rivers based on monthly grab samples?

Abstract Background Water quality assessment must rely on representative samples, but obtaining them is increasingly challenging given the growing number and diversity of trace contaminants emitted into water bodies. This study investigates whether and to what extent monthly grab sampling (GS), widely used in official monitoring programmes, provides reliable and accurate estimates of annual mean and maximum concentrations, and of annual riverine loads. Through a one-year systematic survey in two rivers using three sampling techniques in parallel, we evaluate low-frequency GS against time-proportional composite (TPC) and flow-proportional composite (FPC) sampling. The scope of 450 contaminants encompasses potentially toxic elements (PTE), pharmaceuticals, biocides, pesticides and PFAS, covering a broad diversity of emission patterns and environmental fate. Results For dissolved PTEs and pharmaceuticals, monthly GS delivered approximately correct annual average concentrations, but potential underestimation and overestimation were also observed. Contaminants with seasonal patterns or those emitted during short-term events, such as many pesticides and biocides, PFAS and total PTEs, were not adequately depicted by low-frequency GS, leading to varying degrees of underestimation and seldom also to overestimation. This applies to average annual concentrations but particularly to loads. Integrated composite sampling, especially flow-proportional, performs significantly better for such contaminants. Worthy of attention are cases of low and highly variable concentrations, such as ibuprofen, lindane and PFNA in this study. While integrated composite samples clearly demonstrated their non-negligible presence, monthly GS failed to detect them. Conclusion The widely applied monitoring approach relying on monthly GS is only sufficiently reliable for contaminants being emitted fairly constantly and transported primarily in the dissolved phase. Even then, its good performance is mostly limited to assessing average concentrations and thus chronic exposure, while integrated composite sampling can significantly improve the accuracy of load calculations. For contaminants with variable and dynamic concentration patterns, FPC sampling performs considerably better, especially in terms of load calculations, followed by TPC sampling. However, the latter is simpler to implement. GS-based underestimations pose a significant risk of incorrectly assessing compliance with environmental quality standards if the concentration level in rivers is not very far below or above the thresholds, as was often the case in our study area.

Authors

Institutions

Publication Details

Journal
Environmental Sciences Europe
Published
2026-01-19
DOI
https://doi.org/10.1186/s12302-025-01314-3
Primary Topic
Soil and Water Nutrient Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

How reliable are estimates of trace contaminants in rivers based on monthly grab samples?

Jörg Krampe, Nikolaus Weber, Radmila Milačić, Steffen Kittlaus et al.
Environmental Sciences Europe
Soil and Water Nutrient Dynamics
article

How reliable are estimates of trace contaminants in rivers based on monthly grab samples?

Jörg Krampe, Nikolaus Weber, Radmila Milačić, Steffen Kittlaus, Katarina Kozlica, Jounes Lutterbach, Christine Hufnagl, Ottavia Zoboli
article en

Abstract

Abstract Background Water quality assessment must rely on representative samples, but obtaining them is increasingly challenging given the growing number and diversity of trace contaminants emitted into water bodies. This study investigates whether and to what extent monthly grab sampling (GS), widely used in official monitoring programmes, provides reliable and accurate estimates of annual mean and maximum concentrations, and of annual riverine loads. Through a one-year systematic survey in two rivers using three sampling techniques in parallel, we evaluate low-frequency GS against time-proportional composite (TPC) and flow-proportional composite (FPC) sampling. The scope of 450 contaminants encompasses potentially toxic elements (PTE), pharmaceuticals, biocides, pesticides and PFAS, covering a broad diversity of emission patterns and environmental fate. Results For dissolved PTEs and pharmaceuticals, monthly GS delivered approximately correct annual average concentrations, but potential underestimation and overestimation were also observed. Contaminants with seasonal patterns or those emitted during short-term events, such as many pesticides and biocides, PFAS and total PTEs, were not adequately depicted by low-frequency GS, leading to varying degrees of underestimation and seldom also to overestimation. This applies to average annual concentrations but particularly to loads. Integrated composite sampling, especially flow-proportional, performs significantly better for such contaminants. Worthy of attention are cases of low and highly variable concentrations, such as ibuprofen, lindane and PFNA in this study. While integrated composite samples clearly demonstrated their non-negligible presence, monthly GS failed to detect them. Conclusion The widely applied monitoring approach relying on monthly GS is only sufficiently reliable for contaminants being emitted fairly constantly and transported primarily in the dissolved phase. Even then, its good performance is mostly limited to assessing average concentrations and thus chronic exposure, while integrated composite sampling can significantly improve the accuracy of load calculations. For contaminants with variable and dynamic concentration patterns, FPC sampling performs considerably better, especially in terms of load calculations, followed by TPC sampling. However, the latter is simpler to implement. GS-based underestimations pose a significant risk of incorrectly assessing compliance with environmental quality standards if the concentration level in rivers is not very far below or above the thresholds, as was often the case in our study area.

Environmental Sciences EuropeVol. 38(1)
TU Wien (AT), Jožef Stefan Institute (SI), Jožef Stefan International Postgraduate School (SI)
Clean water and sanitation
Openalex Percentile: Top 85%
Soil and Water Nutrient Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.