Enhancing power quality of pv grid-connected system through mantis shrimp optimization algorithm for optimal Dc bus voltage control

The nonlinear and intermittent nature of Photovoltaic (PV) systems introduces dynamic disturbances that negatively impact the stability of the DC bus voltage (V<sub>dc</sub>) between PV sources and shunt active power filters (SAPFs). These fluctuations pose significant challenges to the performance of SAPFs, especially when the reference DC bus voltage (V<sub>dc</sub>*) is constant and not adapted to the instantaneous operating conditions. In this study, a Perturb and Observe (P&O) algorithm is employed within the PV subsystem to perform Maximum Power Point Tracking (MPPT), further contributing to the time-varying behavior of V<sub>dc</sub>. To address this problem, this paper proposes a real-time optimization strategy based on the Mantis Shrimp Optimization Algorithm (MShOA) for continuous V<sub>dc</sub>* adjustment. This method relies on real-time Total Harmonic Distortion (THD) feedback to dynamically determine the optimal V<sub>dc</sub>*, thereby improving harmonic mitigation and maintaining voltage stability. Simulation results demonstrate that the proposed MShOA-based approach effectively reduces THD from 3.59% to 2.85% obtained with conventional methods to 2.33% before PV injection, and maintains 4.19% after PV injection, remaining within the IEEE 519 - 92 standard limits. To confirm its superiority, a comparison with the Whale Optimization Algorithm (WOA) was performed, which achieved 2.65% before and 5.78% after PV injection. These findings validate the higher accuracy, faster convergence, and better adaptability of the proposed MShOA in ensuring robust voltage regulation and improved power quality under PV injection conditions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-19
DOI
https://doi.org/10.1038/s41598-025-32058-y
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing power quality of pv grid-connected system through mantis shrimp optimization algorithm for optimal Dc bus voltage control

Yakoub Nettari, Feriel Abdelmalek, Alla Eddine Boukhdenna, Salah S. Alharbi et al.
Scientific Reports
Optimal Power Flow Distribution
article

Enhancing power quality of pv grid-connected system through mantis shrimp optimization algorithm for optimal Dc bus voltage control

Yakoub Nettari, Feriel Abdelmalek, Alla Eddine Boukhdenna, Salah S. Alharbi, Saleh S. Alharbi, Djallal Eddine Zabia, Hamza Afghoul
article en

Abstract

The nonlinear and intermittent nature of Photovoltaic (PV) systems introduces dynamic disturbances that negatively impact the stability of the DC bus voltage (V<sub>dc</sub>) between PV sources and shunt active power filters (SAPFs). These fluctuations pose significant challenges to the performance of SAPFs, especially when the reference DC bus voltage (V<sub>dc</sub>*) is constant and not adapted to the instantaneous operating conditions. In this study, a Perturb and Observe (P&O) algorithm is employed within the PV subsystem to perform Maximum Power Point Tracking (MPPT), further contributing to the time-varying behavior of V<sub>dc</sub>. To address this problem, this paper proposes a real-time optimization strategy based on the Mantis Shrimp Optimization Algorithm (MShOA) for continuous V<sub>dc</sub>* adjustment. This method relies on real-time Total Harmonic Distortion (THD) feedback to dynamically determine the optimal V<sub>dc</sub>*, thereby improving harmonic mitigation and maintaining voltage stability. Simulation results demonstrate that the proposed MShOA-based approach effectively reduces THD from 3.59% to 2.85% obtained with conventional methods to 2.33% before PV injection, and maintains 4.19% after PV injection, remaining within the IEEE 519 - 92 standard limits. To confirm its superiority, a comparison with the Whale Optimization Algorithm (WOA) was performed, which achieved 2.65% before and 5.78% after PV injection. These findings validate the higher accuracy, faster convergence, and better adaptability of the proposed MShOA in ensuring robust voltage regulation and improved power quality under PV injection conditions.

Scientific ReportsVol. 16(1)
İstanbul Sabahattin Zaim Üniversitesi (TR), University of Biskra (DZ), Higher National Veterinary School (DZ), University Ferhat Abbas of Setif (DZ), Al Baha University (SA)
Affordable and clean energy
Openalex Percentile: Top 84%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.