Bicarbonate from arterial blood gas analysis as predictor of sleep-related hypoventilation: a diagnostic accuracy study

Background Bicarbonate above the upper limit of normal is used as an indicator of sleep-related hypoventilation in patients with diseases frequently associated with hypoventilation, such as obesity or neuromuscular diseases. Research question The aim was to evaluate the diagnostic accuracy of bicarbonate from daytime arterial blood gas analysis for sleep-related hypoventilation measured via transcutaneous nocturnal capnometry. Methods In a diagnostic accuracy study, the sensitivity and specificity of bicarbonate concentration for detecting nocturnal hypoventilation were tested using a receiver operating curve (ROC) and logistic regression analysis in patients undergoing both an in-laboratory sleep study with transcutaneous capnometry and daytime arterial blood gas analysis. Results In 510 patients (mean±SD age 52±15 years, BMI 34±10 kg/m $^{2}$ ), the area under the ROC curve for bicarbonate (HCO $_{3-}$ ) and median nocturnal tcpCO $_{2}$ ≥50 mm Hg (45% yes, 55% no) was 0.70 (95% CI 0.65 to 0.75). Sensitivity of HCO $_{3-}$ of 26.5 mmol/L and 27.0 mmol/L was 61.0% and 54.1%, specificity 71.3% and 79.6%, and the likelihood ratio for sleep-related hypoventilation (median tcpCO $_{2}$ ≥50 mm Hg) 2.1 and 2.6. HCO $_{3-}$ was significantly higher in those with (n=231, 27.6±3.0 mmol/L) versus without (n=279, 25.8±1.9 mmol/L) sleep-related hypoventilation (p<0.001). Increasing awake HCO $_{3-}$ was associated with a higher likelihood of nocturnal hypoventilation (OR 1.4 (95% CI 1.3 to 1.5), p<0.001). Conclusions The sensitivity of elevated bicarbonate from awake arterial blood gas analysis using common cut-off values such as 27 mmol/L is only moderate, and bicarbonate as an integral part of the assessment of sleep hypoventilation (likelihood ratio) must be interpreted in the context of other assessments. A normal bicarbonate does not rule out sleep hypoventilation.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-06-01
DOI
https://doi.org/10.5167/uzh-282006
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bicarbonate from arterial blood gas analysis as predictor of sleep-related hypoventilation: a diagnostic accuracy study

Michelle Mollet, Esther Irene Schwarz, Joël Julien Herzig, Sanja Pocrncic et al.
Universität Zürich, ZORA
Obstructive Sleep Apnea Research
article

Bicarbonate from arterial blood gas analysis as predictor of sleep-related hypoventilation: a diagnostic accuracy study

Michelle Mollet, Esther Irene Schwarz, Joël Julien Herzig, Sanja Pocrncic, Lara Benning, Malcolm Kohler, Mona Lichtblau, Matteo Bradicich, Laura Mayer, Silvia Ulrich
article en

Abstract

Background Bicarbonate above the upper limit of normal is used as an indicator of sleep-related hypoventilation in patients with diseases frequently associated with hypoventilation, such as obesity or neuromuscular diseases. Research question The aim was to evaluate the diagnostic accuracy of bicarbonate from daytime arterial blood gas analysis for sleep-related hypoventilation measured via transcutaneous nocturnal capnometry. Methods In a diagnostic accuracy study, the sensitivity and specificity of bicarbonate concentration for detecting nocturnal hypoventilation were tested using a receiver operating curve (ROC) and logistic regression analysis in patients undergoing both an in-laboratory sleep study with transcutaneous capnometry and daytime arterial blood gas analysis. Results In 510 patients (mean±SD age 52±15 years, BMI 34±10 kg/m $^{2}$ ), the area under the ROC curve for bicarbonate (HCO $_{3-}$ ) and median nocturnal tcpCO $_{2}$ ≥50 mm Hg (45% yes, 55% no) was 0.70 (95% CI 0.65 to 0.75). Sensitivity of HCO $_{3-}$ of 26.5 mmol/L and 27.0 mmol/L was 61.0% and 54.1%, specificity 71.3% and 79.6%, and the likelihood ratio for sleep-related hypoventilation (median tcpCO $_{2}$ ≥50 mm Hg) 2.1 and 2.6. HCO $_{3-}$ was significantly higher in those with (n=231, 27.6±3.0 mmol/L) versus without (n=279, 25.8±1.9 mmol/L) sleep-related hypoventilation (p<0.001). Increasing awake HCO $_{3-}$ was associated with a higher likelihood of nocturnal hypoventilation (OR 1.4 (95% CI 1.3 to 1.5), p<0.001). Conclusions The sensitivity of elevated bicarbonate from awake arterial blood gas analysis using common cut-off values such as 27 mmol/L is only moderate, and bicarbonate as an integral part of the assessment of sleep hypoventilation (likelihood ratio) must be interpreted in the context of other assessments. A normal bicarbonate does not rule out sleep hypoventilation.

Universität Zürich, ZORA
Good health and well-being
Openalex Percentile: Top 30%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bicarbonate from arterial blood gas analysis as predictor of sleep-related hypoventilation: a diagnostic accuracy study — Michelle Mollet, Esther Irene Schwarz, et al. · Universität Zürich, ZORA (2025) | TGRS Research Map | TGRS