Characterization of the Hamamatsu R12699-406-M4 photomultiplier tube in cold xenon environments

The Hamamatsu R12699-406-M4 is a 2×2 multi-anode 2-inch photomultiplier tube that offers a compact form factor, low intrinsic radioactivity, and high photocathode coverage. These characteristics make it a promising candidate for next-generation xenon-based direct detection dark matter experiments, such as XLZD and PandaX-xT. We present a detailed characterization of this photosensor operated in cold xenon environments, focusing on its single photoelectron response, dark count rate, light emission, and afterpulsing behavior. The device demonstrated a gain exceeding 2·10 $^{6}$ at the nominal voltage of -1.0 kV, along with a low dark count rate of 0.4(2) Hz/cm $^{2}$ . Due to the compact design, afterpulses exhibited short delay times, resulting in some cases in an overlap with the light-induced signal. To evaluate its applicability in a realistic detector environment, two R12699-406-M4 units were deployed in a small-scale dual-phase xenon time projection chamber. The segmented 2×2 anode structure enabled lateral position reconstruction using a single photomultiplier tube, highlighting the potential of the sensor for effective event localization in future detectors.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-12-01
DOI
https://doi.org/10.5167/uzh-282322
Primary Topic
Dark Matter and Cosmic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of the Hamamatsu R12699-406-M4 photomultiplier tube in cold xenon environments

M. Flierman, A. Bismark, M. Adrover, T den Hollander et al.
Universität Zürich, ZORA
Dark Matter and Cosmic Phenomena
article

Characterization of the Hamamatsu R12699-406-M4 photomultiplier tube in cold xenon environments

M. Flierman, A. Bismark, M. Adrover, T den Hollander, M. P. Decowski, J. J. Cuenca-García, Laura Baudis, A. P. Colijn
article en

Abstract

The Hamamatsu R12699-406-M4 is a 2×2 multi-anode 2-inch photomultiplier tube that offers a compact form factor, low intrinsic radioactivity, and high photocathode coverage. These characteristics make it a promising candidate for next-generation xenon-based direct detection dark matter experiments, such as XLZD and PandaX-xT. We present a detailed characterization of this photosensor operated in cold xenon environments, focusing on its single photoelectron response, dark count rate, light emission, and afterpulsing behavior. The device demonstrated a gain exceeding 2·10 $^{6}$ at the nominal voltage of -1.0 kV, along with a low dark count rate of 0.4(2) Hz/cm $^{2}$ . Due to the compact design, afterpulses exhibited short delay times, resulting in some cases in an overlap with the light-induced signal. To evaluate its applicability in a realistic detector environment, two R12699-406-M4 units were deployed in a small-scale dual-phase xenon time projection chamber. The segmented 2×2 anode structure enabled lateral position reconstruction using a single photomultiplier tube, highlighting the potential of the sensor for effective event localization in future detectors.

Universität Zürich, ZORA
Openalex Percentile: Top 19%
Dark Matter and Cosmic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.