Intra-, Epidural And Intracranial Pressure Changes During Interlaminar Endoscopy, With and Without Dural Tear

Objective: Endoscopic spine surgery implies possibly severe complications of the central nervous system, from headache to seizures and autonomic dysreflexia. These adverse events might be due to increased intracranial pressure (ICP), presumably induced by increased spinal intra-/epidural pressure caused by fluid irrigation. This study was designed to perform interlaminar endoscopic lumbar discectomy (IELD) at different irrigation fluid settings while monitoring its effect on intra-/epidural and ICPs, with and without dural tears. Methods: Spinal intradural pressures were measured by introducing catheters through a sacral approach to human cadavers' lumbar, thoracic, and cervical levels. Additionally, an epidural probe was placed at L3-4. ICP was measured by an intraventricular probe. IELD was performed at L3-4, and the effect of varying irrigation pressures by different endoscopic pump systems and gravity-based irrigation on intra-/epidural and ICP pressures was measured before and after durotomy at L3-4. Results: Intradural pressure at L3-4 correlated linearly with increasing irrigation pressure, irrespective of the used pump system (median pressure increase at 100-mmHg irrigation pressure: system I: 7 mmHg, r=0.94, p=0.002; system II: 7 mmHg, r=0.89, p=0.017) or gravity (8 mmHg, r=0.93, p=0.242). This effect was also seen intradurally at the thoracic/cervical spine, epidural, and intracranial level, and was even more pronounced with the maneuver of outflow-occlusion and a dural tear present. Conclusion: While performing IELD, pump pressures correlated linearly to intra-/epidural pressures and ICPs. Pressures did not rise to concerningly high levels without outflow-occlusion, even with increased pump pressures. In the presence of a dural tear, higher pump pressures exacerbated by occlusion may lead to deleterious intradural and ICP elevations.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-06-30
DOI
https://doi.org/10.5167/uzh-282666
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intra-, Epidural And Intracranial Pressure Changes During Interlaminar Endoscopy, With and Without Dural Tear

Jonas Widmer, Najmeh Kheram, Carl Moritz Zipser, José Miguel Spirig et al.
Universität Zürich, ZORA
Cervical and Thoracic Myelopathy
article

Intra-, Epidural And Intracranial Pressure Changes During Interlaminar Endoscopy, With and Without Dural Tear

Jonas Widmer, Najmeh Kheram, Carl Moritz Zipser, José Miguel Spirig, Vincent Hagel, Jana Felicitas Schader, Marie-Rosa Fasser, Mazda Farshad
article en

Abstract

Objective: Endoscopic spine surgery implies possibly severe complications of the central nervous system, from headache to seizures and autonomic dysreflexia. These adverse events might be due to increased intracranial pressure (ICP), presumably induced by increased spinal intra-/epidural pressure caused by fluid irrigation. This study was designed to perform interlaminar endoscopic lumbar discectomy (IELD) at different irrigation fluid settings while monitoring its effect on intra-/epidural and ICPs, with and without dural tears. Methods: Spinal intradural pressures were measured by introducing catheters through a sacral approach to human cadavers' lumbar, thoracic, and cervical levels. Additionally, an epidural probe was placed at L3-4. ICP was measured by an intraventricular probe. IELD was performed at L3-4, and the effect of varying irrigation pressures by different endoscopic pump systems and gravity-based irrigation on intra-/epidural and ICP pressures was measured before and after durotomy at L3-4. Results: Intradural pressure at L3-4 correlated linearly with increasing irrigation pressure, irrespective of the used pump system (median pressure increase at 100-mmHg irrigation pressure: system I: 7 mmHg, r=0.94, p=0.002; system II: 7 mmHg, r=0.89, p=0.017) or gravity (8 mmHg, r=0.93, p=0.242). This effect was also seen intradurally at the thoracic/cervical spine, epidural, and intracranial level, and was even more pronounced with the maneuver of outflow-occlusion and a dural tear present. Conclusion: While performing IELD, pump pressures correlated linearly to intra-/epidural pressures and ICPs. Pressures did not rise to concerningly high levels without outflow-occlusion, even with increased pump pressures. In the presence of a dural tear, higher pump pressures exacerbated by occlusion may lead to deleterious intradural and ICP elevations.

Universität Zürich, ZORA
Openalex Percentile: Top 23%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.