Durability Test of Cold-Bent Insulating Glass Units

Cold-bent glass has been utilized in a number of landmark projects globally, owing to its cost-effectiveness and low carbon footprint. To investigate the impact of cold bending loads on the long-term performance of insulating laminated glass, this paper proposes a durability testing method for cold-bent glass. This method is based on the hypothesis that the failure of the glass sealing system is caused by the cold bending process. It is novel in its use of full-scale glass panel specimens subjected to the maximum design cold-bend curvature to replicate the worst-case sealing boundary conditions present in actual installations. This method comprises three components: cold bending, cyclic immersion in water, and high–low temperature cycling. The durability is evaluated by assessing the laminating condition and sealing performance of the insulating laminated glass before and after testing. In total, 24 insulating glass samples from an actual engineering project were studied by the proposed methodology. The results indicate the following: (1) the proposed method demonstrates strong operational feasibility, suitable for durability testing and the assessment of cold-bent insulating laminated glass across diverse dimensions; (2) no significant quality or sealing issues were observed in the tested samples during the tests, suggesting that durability is minimally affected when the glass’s cold bending warpage is controlled within certain range; and (3) a discernible trend observed in the full-scale test data is that cold bending results in increased misalignment and decreased argon content. These findings provide a valuable reference for the design and construction of cold-bent glass curtain wall projects.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-01-19
DOI
https://doi.org/10.3390/buildings16020406
Primary Topic
Structural Analysis of Composite Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Durability Test of Cold-Bent Insulating Glass Units

Ze Ming Wang, Xichen Zhang, Xiangqiu Fu, Donghai Lin et al.
Buildings
Structural Analysis of Composite Materials
article

Durability Test of Cold-Bent Insulating Glass Units

Ze Ming Wang, Xichen Zhang, Xiangqiu Fu, Donghai Lin, Zhengdi Wu, Xin Tang
article en

Abstract

Cold-bent glass has been utilized in a number of landmark projects globally, owing to its cost-effectiveness and low carbon footprint. To investigate the impact of cold bending loads on the long-term performance of insulating laminated glass, this paper proposes a durability testing method for cold-bent glass. This method is based on the hypothesis that the failure of the glass sealing system is caused by the cold bending process. It is novel in its use of full-scale glass panel specimens subjected to the maximum design cold-bend curvature to replicate the worst-case sealing boundary conditions present in actual installations. This method comprises three components: cold bending, cyclic immersion in water, and high–low temperature cycling. The durability is evaluated by assessing the laminating condition and sealing performance of the insulating laminated glass before and after testing. In total, 24 insulating glass samples from an actual engineering project were studied by the proposed methodology. The results indicate the following: (1) the proposed method demonstrates strong operational feasibility, suitable for durability testing and the assessment of cold-bent insulating laminated glass across diverse dimensions; (2) no significant quality or sealing issues were observed in the tested samples during the tests, suggesting that durability is minimally affected when the glass’s cold bending warpage is controlled within certain range; and (3) a discernible trend observed in the full-scale test data is that cold bending results in increased misalignment and decreased argon content. These findings provide a valuable reference for the design and construction of cold-bent glass curtain wall projects.

BuildingsVol. 16(2)
East China University of Science and Technology (CN), State Key Laboratory of Building Safety and Built Environment (CN), Far East University (KR), China Building Materials Academy (CN), China Academy of Building Research (CN)
Openalex Percentile: Top 84%
Structural Analysis of Composite Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.