The 3D-Printed Customized Femoral Short Stem Offers Improved Anatomical Parameters Restoration, Fitness and Biomechanical Performance Compared With Traditional Femoral Stem

Objective: The traditional femoral stem is unsuitable for patients with severe proximal femoral bone defects or deformities. However, 3D-printed customized designs offer improved proximal femoral canal contact and enhance the initial stability of the femoral prosthesis. Therefore, this study aims to compare the anatomical parameters, contact parameters, and performance of the 3D-printed customized femoral short (CFS) stem with those of the traditional femoral stem following total hip arthroplasty (THA). Methods: An in vitro study simulating THA was performed using artificial femur models, with a 3D-printed CFS stem as the experimental group and a Trilock stem as the control group. Anatomical parameters, fitness, filling, micro-motion, and strain distribution were evaluated using artificial femoral models. Micro-motion and strain were recorded under different simulated bodyweight loading using a 3D digital image correlation measurement system. Results: The neck-shaft angles (NSA) and coronal femoral horizontal offset (CFHO) of the 3D-printed CFS stem (NSA: 125.22°, CFHO: 41.03 mm) were closer to those of the intact femur (NSA: 127.37°, CFHO: 43.27 mm) compare with the Trilock stem (NSA: 132.61°, CFHO: 32.98 mm). In addition, the 3D-printed CFS stem showed improved fitness at cross-sections (The top of the lesser trochanter: 6.31%, the middle of the lesser trochanter: 23.42%, the bottom of the lesser trochanter: 26.61%) and reduced micro-motion under different simulated bodyweight loads (1000: 0.043, 1375: 0.056, 2060 N: 0.061 mm). Conclusions: The 3D-printed CFS stem provides improved restoration of anatomical parameters, enhanced fitness, and superior biomechanical performance compared with the Trilock stem.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-04-01
DOI
https://doi.org/10.5167/uzh-282926
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The 3D-Printed Customized Femoral Short Stem Offers Improved Anatomical Parameters Restoration, Fitness and Biomechanical Performance Compared With Traditional Femoral Stem

Tsung‐Yuan Tsai, Dimitris Dimitriou, Ziang Jiang, Liao Wang et al.
Universität Zürich, ZORA
Orthopaedic implants and arthroplasty
article

The 3D-Printed Customized Femoral Short Stem Offers Improved Anatomical Parameters Restoration, Fitness and Biomechanical Performance Compared With Traditional Femoral Stem

Tsung‐Yuan Tsai, Dimitris Dimitriou, Ziang Jiang, Liao Wang, Yangyang Yang
article en

Abstract

Objective: The traditional femoral stem is unsuitable for patients with severe proximal femoral bone defects or deformities. However, 3D-printed customized designs offer improved proximal femoral canal contact and enhance the initial stability of the femoral prosthesis. Therefore, this study aims to compare the anatomical parameters, contact parameters, and performance of the 3D-printed customized femoral short (CFS) stem with those of the traditional femoral stem following total hip arthroplasty (THA). Methods: An in vitro study simulating THA was performed using artificial femur models, with a 3D-printed CFS stem as the experimental group and a Trilock stem as the control group. Anatomical parameters, fitness, filling, micro-motion, and strain distribution were evaluated using artificial femoral models. Micro-motion and strain were recorded under different simulated bodyweight loading using a 3D digital image correlation measurement system. Results: The neck-shaft angles (NSA) and coronal femoral horizontal offset (CFHO) of the 3D-printed CFS stem (NSA: 125.22°, CFHO: 41.03 mm) were closer to those of the intact femur (NSA: 127.37°, CFHO: 43.27 mm) compare with the Trilock stem (NSA: 132.61°, CFHO: 32.98 mm). In addition, the 3D-printed CFS stem showed improved fitness at cross-sections (The top of the lesser trochanter: 6.31%, the middle of the lesser trochanter: 23.42%, the bottom of the lesser trochanter: 26.61%) and reduced micro-motion under different simulated bodyweight loads (1000: 0.043, 1375: 0.056, 2060 N: 0.061 mm). Conclusions: The 3D-printed CFS stem provides improved restoration of anatomical parameters, enhanced fitness, and superior biomechanical performance compared with the Trilock stem.

Universität Zürich, ZORA
Sustainable cities and communities
Openalex Percentile: Top 23%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.