High-resolution deuterium metabolic imaging of the human brain at 9.4 T using phase-cycled balanced SSFP spectral-spatial acquisitions

Purpose: The aim was to improve the sensitivity and robustness against B inhomogeneities of deuterium metabolic imaging (DMI) using phase-cycled balanced SSFP (bSSFP) methods at 9.4 T. Methods: We investigated two variants of phase-cycled bSSFP acquisitions, namely uniformly weighted multi-echo and acquisition-weighted chemical shift imaging (CSI) to improve the SNR of DMI in the brain after oral [6,6'-H]-glucose intake. Phase-cycling was introduced to reduce the off-resonance sensitivity of bSSFP, incurring a moderate SNR loss. Two SNR optimal methods for obtaining metabolite amplitudes from the phase-cycled bSSFP data were proposed. The SNR performance of the two bSSFP variants was compared with the SNR-optimized vendor's standard CSI. Additionally, in vivo T and T of deuterium metabolites were estimated. Results: High-resolution whole-brain dynamic DMI maps were obtained for all acquisitions. The CSI variant of phase-cycled bSSFP achieved an average SNR increase of 16% and 25% for glucose and glutamate + glutamine (Glx), respectively, compared to the SNR-optimized vendor's standard CSI. Phase-cycling improved the bSSFP metabolite estimation and provided additional spectral encoding at the cost of a 10% to 20% SNR loss. Compared to the CSI variant of bSSFP acquisition, the multi-echo variant exhibited up to 35% lower SNR performance because of uniform k-space weighting and less efficient readout. However, it achieved higher resolutions than acquisition-weighted CSI protocols and showed several qualitative improvements. Conclusion: We demonstrated the feasibility of using two phase-cycled bSSFP acquisitions for off-resonance insensitive high-resolution [6,6'-H]-glucose DMI studies in the human brain. bSSFP acquisitions have potential to improve the sensitivity of DMI despite the SNR loss of phase-cycling and other human scanner constraints.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-10-13
DOI
https://doi.org/10.5167/uzh-282828
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-resolution deuterium metabolic imaging of the human brain at 9.4 T using phase-cycled balanced SSFP spectral-spatial acquisitions

Rahel Heule, Nikolai I. Avdievich, Laura Kuebler, Rolf Pohmann et al.
Universität Zürich, ZORA
Advanced MRI Techniques and Applications
article

High-resolution deuterium metabolic imaging of the human brain at 9.4 T using phase-cycled balanced SSFP spectral-spatial acquisitions

Rahel Heule, Nikolai I. Avdievich, Laura Kuebler, Rolf Pohmann, Georgiy A Solomakha, Praveen Iyyappan Valsala, Klaus Scheffler, André F Martins, Jörn Engelmann
article en

Abstract

Purpose: The aim was to improve the sensitivity and robustness against B inhomogeneities of deuterium metabolic imaging (DMI) using phase-cycled balanced SSFP (bSSFP) methods at 9.4 T. Methods: We investigated two variants of phase-cycled bSSFP acquisitions, namely uniformly weighted multi-echo and acquisition-weighted chemical shift imaging (CSI) to improve the SNR of DMI in the brain after oral [6,6'-H]-glucose intake. Phase-cycling was introduced to reduce the off-resonance sensitivity of bSSFP, incurring a moderate SNR loss. Two SNR optimal methods for obtaining metabolite amplitudes from the phase-cycled bSSFP data were proposed. The SNR performance of the two bSSFP variants was compared with the SNR-optimized vendor's standard CSI. Additionally, in vivo T and T of deuterium metabolites were estimated. Results: High-resolution whole-brain dynamic DMI maps were obtained for all acquisitions. The CSI variant of phase-cycled bSSFP achieved an average SNR increase of 16% and 25% for glucose and glutamate + glutamine (Glx), respectively, compared to the SNR-optimized vendor's standard CSI. Phase-cycling improved the bSSFP metabolite estimation and provided additional spectral encoding at the cost of a 10% to 20% SNR loss. Compared to the CSI variant of bSSFP acquisition, the multi-echo variant exhibited up to 35% lower SNR performance because of uniform k-space weighting and less efficient readout. However, it achieved higher resolutions than acquisition-weighted CSI protocols and showed several qualitative improvements. Conclusion: We demonstrated the feasibility of using two phase-cycled bSSFP acquisitions for off-resonance insensitive high-resolution [6,6'-H]-glucose DMI studies in the human brain. bSSFP acquisitions have potential to improve the sensitivity of DMI despite the SNR loss of phase-cycling and other human scanner constraints.

Universität Zürich, ZORA
Openalex Percentile: Top 28%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.