Exploring Dental Anatomy: An Ex Vivo Comparative Study Between Photon‐Counting Detector CT and Cone‐Beam CT

Objectives The aim of this ex vivo study was to assess the performance of photon‐counting detector computed tomography (PCD‐CT) compared with cone‐beam computed tomography (CBCT) at equivalent radiation doses for detecting and evaluating mandibular and dental anatomical structures in porcine cadavers. Material and Methods This intermodal comparative study evaluated imaging protocols at three radiation dose levels (high: 360 μSv, standard: 145 μSv, low: 20 μSv) in six porcine cadaver heads, analyzing 12 CBCT and 18 PCD‐CT volumes. Two blinded observers assessed image quality, artifact susceptibility, and diagnostic interpretability using a 5‐point Likert scale (5 = highest, 1 = lowest). Statistical analysis included descriptive statistics and interobserver reliability, assessed by weighted kappa (κ) analysis. Results PCD‐CT either matched or outperformed CBCT at standard‐ and low‐dose protocols, demonstrating superior anatomy coverage, density, contrast, and less artifact susceptibility. High‐ and standard‐dose protocols achieved perfect scores 5 (SD = 0). At low‐dose levels, PCD‐CT showed slightly lower scores but still outperformed CBCT. PCD‐CT showed minimal artifacts, with no significant artifacts in high and standard doses. Inter‐ and intra‐reader reliability was higher for PCD‐CT (κ: 0.694–1; p < 0.001) compared to CBCT (0.55–0.916; p < 0.001), with the difference being largest at low doses. Conclusion PCD‐CT outperforms CBCT in diagnostic interpretability and artifact reduction across various radiation dose levels, offering a promising alternative for dentomaxillofacial imaging that aligns with the ALADAIP principle.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-12-01
DOI
https://doi.org/10.5167/uzh-281843
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring Dental Anatomy: An Ex Vivo Comparative Study Between Photon‐Counting Detector CT and Cone‐Beam CT

Silvio Valdec, Thomas Frauenfelder, Bernd Stadlinger, Harald Essig et al.
Universität Zürich, ZORA
Dental Radiography and Imaging
article

Exploring Dental Anatomy: An Ex Vivo Comparative Study Between Photon‐Counting Detector CT and Cone‐Beam CT

Silvio Valdec, Thomas Frauenfelder, Bernd Stadlinger, Harald Essig, Rubens Spin‐Neto, Victor Mergen, Hatem Alkadhi, Fabian Benz, Sebastian Winklhofer, Adib Al-Haj Husain
article en

Abstract

Objectives The aim of this ex vivo study was to assess the performance of photon‐counting detector computed tomography (PCD‐CT) compared with cone‐beam computed tomography (CBCT) at equivalent radiation doses for detecting and evaluating mandibular and dental anatomical structures in porcine cadavers. Material and Methods This intermodal comparative study evaluated imaging protocols at three radiation dose levels (high: 360 μSv, standard: 145 μSv, low: 20 μSv) in six porcine cadaver heads, analyzing 12 CBCT and 18 PCD‐CT volumes. Two blinded observers assessed image quality, artifact susceptibility, and diagnostic interpretability using a 5‐point Likert scale (5 = highest, 1 = lowest). Statistical analysis included descriptive statistics and interobserver reliability, assessed by weighted kappa (κ) analysis. Results PCD‐CT either matched or outperformed CBCT at standard‐ and low‐dose protocols, demonstrating superior anatomy coverage, density, contrast, and less artifact susceptibility. High‐ and standard‐dose protocols achieved perfect scores 5 (SD = 0). At low‐dose levels, PCD‐CT showed slightly lower scores but still outperformed CBCT. PCD‐CT showed minimal artifacts, with no significant artifacts in high and standard doses. Inter‐ and intra‐reader reliability was higher for PCD‐CT (κ: 0.694–1; p < 0.001) compared to CBCT (0.55–0.916; p < 0.001), with the difference being largest at low doses. Conclusion PCD‐CT outperforms CBCT in diagnostic interpretability and artifact reduction across various radiation dose levels, offering a promising alternative for dentomaxillofacial imaging that aligns with the ALADAIP principle.

Universität Zürich, ZORA
Openalex Percentile: Top 26%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exploring Dental Anatomy: An Ex Vivo Comparative Study Between Photon‐Counting Detector CT and Cone‐Beam CT — Silvio Valdec, Thomas Frauenfelder, et al. · Universität Zürich, ZORA (2025) | TGRS Research Map | TGRS