Reproducing Anisotropic Properties in Personalized Mitral Valve Models to Improve Hemodynamic Behavior

Abstract Mitral valve insufficiency can be surgically corrected by minimally invasive mitral valve surgery. This approach is difficult to learn and training opportunities are still limited. Therefore, we built a physical mitral valve flow simulator to accommodate patient-individual valve models. The models must fulfill certain material properties to replicate adequate dynamic behavior, while being surgically modifiable. We developed two approaches for manufacturing complex anisotropic physiological mitral valve tissue, the first one being a thermoformed thermoplastic urethan (TPU) film and the second one being a mesh reinforced silicone cast into a 3D printed mold. The valve models were mounted into a pulsatile flow simulator, on which their hemodynamic performance before and after ring annuloplasty was evaluated by common flow measurements. Out of the presented approaches, the anisotropic mesh reinforced valve performed best, creating larger coaptation height and thereby enabling higher endsystolic pressures and significantly larger cardiac outputs.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2025-12-01
DOI
https://doi.org/10.1515/cdbme-2025-0309
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducing Anisotropic Properties in Personalized Mitral Valve Models to Improve Hemodynamic Behavior

Wilfried V. Liebig, Gabriele Romano, Sandy Engelhardt, Sarah K. Müller et al.
Current Directions in Biomedical Engineering
Cardiac Valve Diseases and Treatments
article

Reproducing Anisotropic Properties in Personalized Mitral Valve Models to Improve Hemodynamic Behavior

Wilfried V. Liebig, Gabriele Romano, Sandy Engelhardt, Sarah K. Müller, Matthias Karck, C. Sören Bergt, Roger Karl
article en

Abstract

Abstract Mitral valve insufficiency can be surgically corrected by minimally invasive mitral valve surgery. This approach is difficult to learn and training opportunities are still limited. Therefore, we built a physical mitral valve flow simulator to accommodate patient-individual valve models. The models must fulfill certain material properties to replicate adequate dynamic behavior, while being surgically modifiable. We developed two approaches for manufacturing complex anisotropic physiological mitral valve tissue, the first one being a thermoformed thermoplastic urethan (TPU) film and the second one being a mesh reinforced silicone cast into a 3D printed mold. The valve models were mounted into a pulsatile flow simulator, on which their hemodynamic performance before and after ring annuloplasty was evaluated by common flow measurements. Out of the presented approaches, the anisotropic mesh reinforced valve performed best, creating larger coaptation height and thereby enabling higher endsystolic pressures and significantly larger cardiac outputs.

Current Directions in Biomedical EngineeringVol. 11(2)
Heidelberg University (DE), University Hospital Heidelberg (DE)
Openalex Percentile: Top 29%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.