Potential Control of a Single Open Bipolar Electrode in an Array Device Using an Ion-Selective Electrode and Ag/AgCl Electrode

An electrochemical circuit containing a control unit is used to control the interfacial potential difference between the bipolar electrodes (BPEs) and the electrolyte solution in an open bipolar system.The control unit consists of a polymeric Na + ion-selective electrode (ISE) connected to a BPE and an Ag/AgCl wire, which connects the electrolyte solution in the control unit to the main chamber via the BPEs.The BPEs contain openings with exposed platinum areas, which serve as cathodic and anodic poles and a potential-determining element.The interfacial potential difference between the potential-determining opening (PDO) and the electrolyte solution can be determined by applying Kirchhoff's second law to the closed circuit containing the PDO, ISE, and Ag/AgCl wire.In the open bipolar system, the intensity of the electrochemiluminescence signal measured for analysis varies depending on the position of the opening of the BPEs.The results suggest that the interfacial potential difference between the anodic and cathodic poles can be varied with a control unit by avoiding ionic crosstalk.

Authors

Institutions

Publication Details

Journal
Electrochemistry
Published
2026-01-15
DOI
https://doi.org/10.5796/electrochemistry.25-00175
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Potential Control of a Single Open Bipolar Electrode in an Array Device Using an Ion-Selective Electrode and Ag/AgCl Electrode

Nurul Asyikeen Ab Mutalib, Yi Deng, 辻村 清也, Jian XIONG et al.
Electrochemistry
Analytical Chemistry and Sensors
article

Potential Control of a Single Open Bipolar Electrode in an Array Device Using an Ion-Selective Electrode and Ag/AgCl Electrode

Nurul Asyikeen Ab Mutalib, Yi Deng, 辻村 清也, Jian XIONG, Hiroaki SUZUKI
article en

Abstract

An electrochemical circuit containing a control unit is used to control the interfacial potential difference between the bipolar electrodes (BPEs) and the electrolyte solution in an open bipolar system.The control unit consists of a polymeric Na + ion-selective electrode (ISE) connected to a BPE and an Ag/AgCl wire, which connects the electrolyte solution in the control unit to the main chamber via the BPEs.The BPEs contain openings with exposed platinum areas, which serve as cathodic and anodic poles and a potential-determining element.The interfacial potential difference between the potential-determining opening (PDO) and the electrolyte solution can be determined by applying Kirchhoff's second law to the closed circuit containing the PDO, ISE, and Ag/AgCl wire.In the open bipolar system, the intensity of the electrochemiluminescence signal measured for analysis varies depending on the position of the opening of the BPEs.The results suggest that the interfacial potential difference between the anodic and cathodic poles can be varied with a control unit by avoiding ionic crosstalk.

ElectrochemistryVol. 94(2)
University of Tsukuba (JP)
Affordable and clean energy
Openalex Percentile: Top 86%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Potential Control of a Single Open Bipolar Electrode in an Array Device Using an Ion-Selective Electrode and Ag/AgCl Electrode — Nurul Asyikeen Ab Mutalib, Yi Deng, et al. · Electrochemistry (2026) | TGRS Research Map | TGRS