A comparison of the released forces from three different types of nickel-titanium wires at three different deflection positions: an in-vitro study

NiTi archwires are distinguished by their ability to deliver gentle, continuous forces over a wide activation range, over time, their crystalline structure has evolved: beginning with conventional NiTi, progressing to super-elastic variants, and then advancing to heat-activated. In this study, we examined three 0.016″ × 0.022″ NiTi rectangular wires: (1) super-elastic NT3 SE®, (2) heat-activated Thermal Ti-D® (active at ~ 25 °C), and (3) heat-activated Thermal Ti-Lite® (~ 35 °C)—by measuring their force release at molar, premolar, and incisor positions to determine whether unloading forces differ by location. A randomized, in-vitro trial was conducted at Aleppo University. Each group included six 30 mm wire sections for each wire type and position (total n = 18 per position). A three-point bending test at 37 °C (Deflection: 3.1 mm at 1 mm/min over a 10 mm span) measured unloading forces at 0.5, 1-, 2-, and 3-mm. Plateau length (3 to 0.5 mm), average force, and slope were recorded. Data were analyzed using one-way ANOVA with post-hoc Sidak’s test; reliability was confirmed via Pearson correlation (r = 0.877). NT3 SE® and Thermal Ti-D® wires showed similar unloading forces across positions (molar: 2.65 ± 0.11, 1.60 ± 0.18, 1.40 ± 0.18, 1.09 ± 0.19 N; incisor: 2.55 ± 0.12, 1.50 ± 0.18, 1.30 ± 0.18, 1.00 ± 0.15 N at 3, 2, 1, and 0.5 mm, respectively), with molar values approximately 10% higher than incisor values; differences were not statistically significant (p > 0.05), and 95% confidence intervals overlapped. Thermal Ti Lite® wires exhibited significantly lower forces overall and clear site-dependent differences (molar: 2.28 ± 0.21, 1.76 ± 0.10, 0.52 ± 0.09, 0.56 ± 0.14 N; premolar: 1.92 ± 0.12, 0.56 ± 0.10, 0.32 ± 0.09, 0.31 ± 0.09 N; incisor: 1.57 ± 0.20, 0.36 ± 0.10, 0.12 ± 0.09, 0.12 ± 0.09 N at 3, 2, 1, and 0.5 mm, respectively), with molar forces on average 50% higher than premolar and 70% higher than incisor values (p < 0.05); average and slope also varied significantly by position, though plateau lengths were consistent—only Ti Lite® showed positional force variability. Thermal Ti-Lite® archwires, with higher austenite-finish temperature (~ 34 °C), demonstrated significant positional force differences, suggesting their potential for site-specific biomechanical control. In contrast, NT3-SE® and Thermal Ti-D® provided uniform force profiles across arch positions. Considering crystalline transformation temperatures and anatomical variation may improve clinical force application during alignment.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-01-16
DOI
https://doi.org/10.1186/s12903-026-07695-y
Primary Topic
Shape Memory Alloy Transformations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparison of the released forces from three different types of nickel-titanium wires at three different deflection positions: an in-vitro study

Mariam M. Masaes, Mohammad Younis Hajeer, Feras Baba, Odday S. Al-Horini
BMC Oral Health
Shape Memory Alloy Transformations
article

A comparison of the released forces from three different types of nickel-titanium wires at three different deflection positions: an in-vitro study

Mariam M. Masaes, Mohammad Younis Hajeer, Feras Baba, Odday S. Al-Horini
article en

Abstract

NiTi archwires are distinguished by their ability to deliver gentle, continuous forces over a wide activation range, over time, their crystalline structure has evolved: beginning with conventional NiTi, progressing to super-elastic variants, and then advancing to heat-activated. In this study, we examined three 0.016″ × 0.022″ NiTi rectangular wires: (1) super-elastic NT3 SE®, (2) heat-activated Thermal Ti-D® (active at ~ 25 °C), and (3) heat-activated Thermal Ti-Lite® (~ 35 °C)—by measuring their force release at molar, premolar, and incisor positions to determine whether unloading forces differ by location. A randomized, in-vitro trial was conducted at Aleppo University. Each group included six 30 mm wire sections for each wire type and position (total n = 18 per position). A three-point bending test at 37 °C (Deflection: 3.1 mm at 1 mm/min over a 10 mm span) measured unloading forces at 0.5, 1-, 2-, and 3-mm. Plateau length (3 to 0.5 mm), average force, and slope were recorded. Data were analyzed using one-way ANOVA with post-hoc Sidak’s test; reliability was confirmed via Pearson correlation (r = 0.877). NT3 SE® and Thermal Ti-D® wires showed similar unloading forces across positions (molar: 2.65 ± 0.11, 1.60 ± 0.18, 1.40 ± 0.18, 1.09 ± 0.19 N; incisor: 2.55 ± 0.12, 1.50 ± 0.18, 1.30 ± 0.18, 1.00 ± 0.15 N at 3, 2, 1, and 0.5 mm, respectively), with molar values approximately 10% higher than incisor values; differences were not statistically significant (p > 0.05), and 95% confidence intervals overlapped. Thermal Ti Lite® wires exhibited significantly lower forces overall and clear site-dependent differences (molar: 2.28 ± 0.21, 1.76 ± 0.10, 0.52 ± 0.09, 0.56 ± 0.14 N; premolar: 1.92 ± 0.12, 0.56 ± 0.10, 0.32 ± 0.09, 0.31 ± 0.09 N; incisor: 1.57 ± 0.20, 0.36 ± 0.10, 0.12 ± 0.09, 0.12 ± 0.09 N at 3, 2, 1, and 0.5 mm, respectively), with molar forces on average 50% higher than premolar and 70% higher than incisor values (p < 0.05); average and slope also varied significantly by position, though plateau lengths were consistent—only Ti Lite® showed positional force variability. Thermal Ti-Lite® archwires, with higher austenite-finish temperature (~ 34 °C), demonstrated significant positional force differences, suggesting their potential for site-specific biomechanical control. In contrast, NT3-SE® and Thermal Ti-D® provided uniform force profiles across arch positions. Considering crystalline transformation temperatures and anatomical variation may improve clinical force application during alignment.

BMC Oral HealthVol. 26(1)
University of Aleppo (SY), Damascus University (SY)
Openalex Percentile: Top 86%
Shape Memory Alloy Transformations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.