Breaking through lag: enhancing intradermal electro-osmotic flow and the future of delay-free continuous glucose monitoring

Diabetes mellitus represents one of the most widespread chronic diseases globally, characterized by alterations in glucose metabolism that require constant monitoring of blood glucose levels. Traditionally, blood testing has been the standard for glucose monitoring; however, interstitial fluid has emerged as a viable alternative, due to its less invasive nature which enhances user comfort. Despite improvements in technology, the accuracy of currently available continuous glucose monitors remains a concern, particularly when the rate of change is higher, such as in hypoglycemic and hyperglycemic ranges. Effective management of hypoglycemia relies on the monitor's ability to provide precise and specific readings when blood glucose levels drop dangerously low. In this context, the demand for heightened accuracy is paramount to timely alert users to impending hypoglycemic events. The inaccuracies of these sensors are attributed to the dynamics of the sample analysis. Specifically the interstitial fluid experiences a delay in concentration due to the diffusion process from capillary blood to interstitial fluid. In this study, we developed a microfluidic device that simulates the diffusion dynamics from capillary glucose to interstitial fluid. We demonstrate the reduction of lag time diffusion from 20 min to 5 min by increasing dermal electro-osmotic flow, which generates convection that transports glucose faster than diffusion, thus resulting in lower lag times. These findings highlight the potential of inciting electro-osmotic flow for improving the responsiveness and accuracy of CGMs, ultimately enhancing diabetes management for users.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-01-16
DOI
https://doi.org/10.3389/fbioe.2025.1717650
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breaking through lag: enhancing intradermal electro-osmotic flow and the future of delay-free continuous glucose monitoring

Alessandro Zompanti, Nurul Izni Rusli, Ruben Van den Eeckhoudt, Irene Taurino et al.
Frontiers in Bioengineering and Biotechnology
Advancements in Transdermal Drug Delivery
article

Breaking through lag: enhancing intradermal electro-osmotic flow and the future of delay-free continuous glucose monitoring

Alessandro Zompanti, Nurul Izni Rusli, Ruben Van den Eeckhoudt, Irene Taurino, Giorgio Pennazza, Lazzaro di Biase, Davide Ciarrocchi, Marco Santonico, Simone Grasso
article en

Abstract

Diabetes mellitus represents one of the most widespread chronic diseases globally, characterized by alterations in glucose metabolism that require constant monitoring of blood glucose levels. Traditionally, blood testing has been the standard for glucose monitoring; however, interstitial fluid has emerged as a viable alternative, due to its less invasive nature which enhances user comfort. Despite improvements in technology, the accuracy of currently available continuous glucose monitors remains a concern, particularly when the rate of change is higher, such as in hypoglycemic and hyperglycemic ranges. Effective management of hypoglycemia relies on the monitor's ability to provide precise and specific readings when blood glucose levels drop dangerously low. In this context, the demand for heightened accuracy is paramount to timely alert users to impending hypoglycemic events. The inaccuracies of these sensors are attributed to the dynamics of the sample analysis. Specifically the interstitial fluid experiences a delay in concentration due to the diffusion process from capillary blood to interstitial fluid. In this study, we developed a microfluidic device that simulates the diffusion dynamics from capillary glucose to interstitial fluid. We demonstrate the reduction of lag time diffusion from 20 min to 5 min by increasing dermal electro-osmotic flow, which generates convection that transports glucose faster than diffusion, thus resulting in lower lag times. These findings highlight the potential of inciting electro-osmotic flow for improving the responsiveness and accuracy of CGMs, ultimately enhancing diabetes management for users.

Frontiers in Bioengineering and BiotechnologyVol. 13
Università Campus Bio-Medico (IT), Astronomy and Space (AU), Universiti Malaysia Perlis (MY), KU Leuven (BE)
Quality Education
Openalex Percentile: Top 85%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.