Real-Time Correction Algorithm for a Chromatographic Background Based on Numerical Algorithm

Although numerous baseline correction methods exist, most are confined to static post-elution processing and fail to meet real-time analysis requirements. To address this, we propose a real-time baseline estimation method based on the Informer time-series prediction model that performs correction during data acquisition without waiting for complete elution. Our work focuses on three key aspects: chromatographic dataset construction, model training, and baseline prediction. Simulation experiments demonstrate that the proposed method achieves comparable accuracy to conventional static processing approaches while exhibiting significant real-time advantages. In processing real chromatographic data, the model achieves a 98.3% chromatographic peak retention rate, with a single computation time of approximately 35 ms—substantially shorter than typical chromatographic sampling cycles (600–900 ms), thus fully satisfying the quantitative analysis requirements for real-time background subtraction.

Authors

Institutions

Publication Details

Journal
Separations
Published
2026-01-16
DOI
https://doi.org/10.3390/separations13010034
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Correction Algorithm for a Chromatographic Background Based on Numerical Algorithm

Jinlin Chen, Yiquan Wu, Xinmei Xu
Separations
Analytical Chemistry and Chromatography
article

Real-Time Correction Algorithm for a Chromatographic Background Based on Numerical Algorithm

Jinlin Chen, Yiquan Wu, Xinmei Xu
article en

Abstract

Although numerous baseline correction methods exist, most are confined to static post-elution processing and fail to meet real-time analysis requirements. To address this, we propose a real-time baseline estimation method based on the Informer time-series prediction model that performs correction during data acquisition without waiting for complete elution. Our work focuses on three key aspects: chromatographic dataset construction, model training, and baseline prediction. Simulation experiments demonstrate that the proposed method achieves comparable accuracy to conventional static processing approaches while exhibiting significant real-time advantages. In processing real chromatographic data, the model achieves a 98.3% chromatographic peak retention rate, with a single computation time of approximately 35 ms—substantially shorter than typical chromatographic sampling cycles (600–900 ms), thus fully satisfying the quantitative analysis requirements for real-time background subtraction.

SeparationsVol. 13(1)
Changzhou Institute of Technology (CN), Huainan Normal University (CN), Nanjing University of Aeronautics and Astronautics (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 86%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.