Ventricular Septal Defect and Complete Atrioventricular Block Following Transcatheter Aortic Valve Implantation: A Case Report

Transcatheter aortic valve implantation (TAVI) is an established alternative to surgical aortic valve replacement for severe aortic stenosis (AS) in high-risk patients, yet rare, potentially life-threatening complications still occur.We describe a 75-year-old man with severe symptomatic AS who underwent TAVI using a balloon-expandable Myval prosthesis; the procedure was complicated by complete atrioventricular block requiring permanent pacemaker implantation.At 1-month follow-up, he presented with dyspnea.Transthoracic echocardiography demonstrated a newly developed perimembranous ventricular septal defect (VSD) adjacent to the prosthetic valve, resulting in a significant left-to-right shunt.This case underscores the need for meticulous pre-procedural assessment of the distribution of calcification, careful procedural planning and technique, and post-procedural vigilance for both conduction disturbances and rare structural complications, such as VSD, following TAVI.

Authors

Publication Details

Journal
International Journal of the Cardiovascular Academy
Published
2026-01-16
DOI
https://doi.org/10.4274/ijca.2025.33042
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventricular Septal Defect and Complete Atrioventricular Block Following Transcatheter Aortic Valve Implantation: A Case Report

Kayıhan Karaman, Elnur Alizade
International Journal of the Cardiovascular Academy
Cardiac Valve Diseases and Treatments
article

Ventricular Septal Defect and Complete Atrioventricular Block Following Transcatheter Aortic Valve Implantation: A Case Report

Kayıhan Karaman, Elnur Alizade
article en

Abstract

Transcatheter aortic valve implantation (TAVI) is an established alternative to surgical aortic valve replacement for severe aortic stenosis (AS) in high-risk patients, yet rare, potentially life-threatening complications still occur.We describe a 75-year-old man with severe symptomatic AS who underwent TAVI using a balloon-expandable Myval prosthesis; the procedure was complicated by complete atrioventricular block requiring permanent pacemaker implantation.At 1-month follow-up, he presented with dyspnea.Transthoracic echocardiography demonstrated a newly developed perimembranous ventricular septal defect (VSD) adjacent to the prosthetic valve, resulting in a significant left-to-right shunt.This case underscores the need for meticulous pre-procedural assessment of the distribution of calcification, careful procedural planning and technique, and post-procedural vigilance for both conduction disturbances and rare structural complications, such as VSD, following TAVI.

International Journal of the Cardiovascular Academy
Zero hunger, Good health and well-being
Openalex Percentile: Top 87%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ventricular Septal Defect and Complete Atrioventricular Block Following Transcatheter Aortic Valve Implantation: A Case Report — Kayıhan Karaman, Elnur Alizade · International Journal of the Cardiovascular Academy (2026) | TGRS Research Map | TGRS