Scaling Up from LV to MV Cable Splice Design Through the Innovative Three-Leg Approach: PD-Free and Life-Compliant Design

Reliability of medium-voltage (MV) cable systems, for distribution to industrial and renewable plants, is becoming an issue for various reasons, among which are increased global aging, unconventional voltage waveforms, and insufficient commissioning tests. The major component undergoing premature failures is splices, and most of those failures can be associated with flaws in installation, commissioning and, in general, workmanship. One of the topics of an ongoing Department of Energy (DOE) Advanced Research Projects Agency-Energy (ARPA-E) project, GOPHURRS, is, indeed, to increase splice reliability through simpler design and installation procedures, which can minimize assembly and aging risks. This paper deals with design and testing techniques, which can allow scaling up to MV, a type of splice design and assembly that has been successful in low-voltage (LV) applications. A new design paradigm, the three-leg approach, is applied for the first time to LV splices to evaluate their operation likelihood and reliability up to 30 kV nominal voltage, allowing intrinsic life to reach the specified target (e.g., 30 years at a failure probability of 5%) and preventing extrinsic aging, namely, partial discharge occurrence. Design principles and validation, including accelerated aging and forensic observations, are presented and discussed.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-01-16
DOI
https://doi.org/10.3390/en19020449
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scaling Up from LV to MV Cable Splice Design Through the Innovative Three-Leg Approach: PD-Free and Life-Compliant Design

Jean Pierre Uwiringiyimana, Myneni Sukesh Babu, Cameron Williams, Gian Carlo Montanari et al.
Energies
High voltage insulation and dielectric phenomena
article

Scaling Up from LV to MV Cable Splice Design Through the Innovative Three-Leg Approach: PD-Free and Life-Compliant Design

Jean Pierre Uwiringiyimana, Myneni Sukesh Babu, Cameron Williams, Gian Carlo Montanari, Mark Melni
article en

Abstract

Reliability of medium-voltage (MV) cable systems, for distribution to industrial and renewable plants, is becoming an issue for various reasons, among which are increased global aging, unconventional voltage waveforms, and insufficient commissioning tests. The major component undergoing premature failures is splices, and most of those failures can be associated with flaws in installation, commissioning and, in general, workmanship. One of the topics of an ongoing Department of Energy (DOE) Advanced Research Projects Agency-Energy (ARPA-E) project, GOPHURRS, is, indeed, to increase splice reliability through simpler design and installation procedures, which can minimize assembly and aging risks. This paper deals with design and testing techniques, which can allow scaling up to MV, a type of splice design and assembly that has been successful in low-voltage (LV) applications. A new design paradigm, the three-leg approach, is applied for the first time to LV splices to evaluate their operation likelihood and reliability up to 30 kV nominal voltage, allowing intrinsic life to reach the specified target (e.g., 30 years at a failure probability of 5%) and preventing extrinsic aging, namely, partial discharge occurrence. Design principles and validation, including accelerated aging and forensic observations, are presented and discussed.

EnergiesVol. 19(2)
Florida State University (US), Mellanox Technologies (United States) (US)
U.S. Department of Energy
Openalex Percentile: Top 86%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Scaling Up from LV to MV Cable Splice Design Through the Innovative Three-Leg Approach: PD-Free and Life-Compliant Design — Jean Pierre Uwiringiyimana, Myneni Sukesh Babu, et al. · Energies (2026) | TGRS Research Map | TGRS