Rapid and non-invasive diagnosis of gingivitis using an uncoated optical fiber-based Mach-Zehnder interferometer salivary pH sensor

In this study, an uncoated optical fiber–based Mach–Zehnder interferometer (SMF–NCF–SMF) salivary pH sensor is developed and experimentally evaluated as a rapid, non-invasive diagnostic tool for gingivitis screening. The sensor exploits multimode interference and refractive index sensitivity, enabling wavelength-shift demodulation of pH-induced spectral changes in saliva. Clinical validation was performed on 83 individuals, of whom 38 exhibited clinically healthy gingiva, and 37 were diagnosed with gingivitis. The proposed sensing structure demonstrated a sensitivity of 1.5 nm/pH and strong linearity exceeding 98%, with gingivitis patients exhibiting significantly more alkaline salivary conditions compared with healthy subjects (p < 0.001). To further support diagnostic reliability, salivary IL-1β levels were quantified using ELISA, revealing elevated concentrations in gingivitis cases and reinforcing the association between salivary biochemical changes and inflammatory periodontal status. The presented optical fiber sensor exhibits high stability, rapid response, and clinical feasibility, highlighting its potential as a practical chairside screening tool for early gingivitis detection.

Authors

Publication Details

Journal
Optics Continuum
Published
2026-01-16
DOI
https://doi.org/10.1364/optcon.583653
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid and non-invasive diagnosis of gingivitis using an uncoated optical fiber-based Mach-Zehnder interferometer salivary pH sensor

hamsa tawfeeq, Abdulhadi Al-Janabi
Optics Continuum
Advanced Fiber Optic Sensors
article

Rapid and non-invasive diagnosis of gingivitis using an uncoated optical fiber-based Mach-Zehnder interferometer salivary pH sensor

hamsa tawfeeq, Abdulhadi Al-Janabi
article en

Abstract

In this study, an uncoated optical fiber–based Mach–Zehnder interferometer (SMF–NCF–SMF) salivary pH sensor is developed and experimentally evaluated as a rapid, non-invasive diagnostic tool for gingivitis screening. The sensor exploits multimode interference and refractive index sensitivity, enabling wavelength-shift demodulation of pH-induced spectral changes in saliva. Clinical validation was performed on 83 individuals, of whom 38 exhibited clinically healthy gingiva, and 37 were diagnosed with gingivitis. The proposed sensing structure demonstrated a sensitivity of 1.5 nm/pH and strong linearity exceeding 98%, with gingivitis patients exhibiting significantly more alkaline salivary conditions compared with healthy subjects (p < 0.001). To further support diagnostic reliability, salivary IL-1β levels were quantified using ELISA, revealing elevated concentrations in gingivitis cases and reinforcing the association between salivary biochemical changes and inflammatory periodontal status. The presented optical fiber sensor exhibits high stability, rapid response, and clinical feasibility, highlighting its potential as a practical chairside screening tool for early gingivitis detection.

Optics ContinuumVol. 5(2)
Openalex Percentile: Top 86%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.