Influence of MR thermometry on predicted temperature during regional hyperthermia treatment

Hyperthermia treatment involves heating tissues to 40–44 °C in order to enhance the efficacy of radiotherapy and/or chemotherapy. Temperature increase is usually induced by the constructive interference of several electromagnetic waves radiating from external sources and can be monitored using magnetic resonance (MR) thermometry. This study aimed to predict temperature increases from non-invasive MR thermometry electromagnetic exposure during deep regional hyperthermia treatment. A 1.5T MR birdcage coil was tuned to produce a homogeneous B1+ field and simulated together with the Sigma Eye hyperthermia applicator and three available patient models. Results show that electromagnetic exposure during MR measurements increases temperature by 0.027 °C, which is, in the hyperthermia temperature range, insignificant. In addition, our results show that the predicted B1+ field homogeneity was influenced by object size and material properties, especially by the water bolus filling the inner part of the applicator.

Authors

Institutions

Publication Details

Journal
Acta Polytechnica
Published
2026-01-15
DOI
https://doi.org/10.14311/ap.2025.65.0705
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of MR thermometry on predicted temperature during regional hyperthermia treatment

Tomas Drizdal, Michael Vydra
Acta Polytechnica
Ultrasound and Hyperthermia Applications
article

Influence of MR thermometry on predicted temperature during regional hyperthermia treatment

Tomas Drizdal, Michael Vydra
article en

Abstract

Hyperthermia treatment involves heating tissues to 40–44 °C in order to enhance the efficacy of radiotherapy and/or chemotherapy. Temperature increase is usually induced by the constructive interference of several electromagnetic waves radiating from external sources and can be monitored using magnetic resonance (MR) thermometry. This study aimed to predict temperature increases from non-invasive MR thermometry electromagnetic exposure during deep regional hyperthermia treatment. A 1.5T MR birdcage coil was tuned to produce a homogeneous B1+ field and simulated together with the Sigma Eye hyperthermia applicator and three available patient models. Results show that electromagnetic exposure during MR measurements increases temperature by 0.027 °C, which is, in the hyperthermia temperature range, insignificant. In addition, our results show that the predicted B1+ field homogeneity was influenced by object size and material properties, especially by the water bolus filling the inner part of the applicator.

Acta PolytechnicaVol. 65(6)
Czech Technical University in Prague (CZ)
Clean water and sanitation
Openalex Percentile: Top 87%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of MR thermometry on predicted temperature during regional hyperthermia treatment — Tomas Drizdal, Michael Vydra · Acta Polytechnica (2026) | TGRS Research Map | TGRS