Subsurface exploration for soil geotechnical properties: Implications for infrastructure design and construction in Victoria Island, Lagos, Nigeria

An exploration of subsurface soil properties has been conducted at a proposed construction site in the aquatic city of Lagos, Nigeria, through the integration of geotechnical and geophysical methods. The aim was to characterise the soil properties and assess their implications for the proposed multi-storey infrastructure. Standard Penetration Tests (6), Dutch Cone Penetrometer Tests (14), and dipole-dipole and pole-dipole electrical resistivity imaging were conducted at the site. The topsoil, consisting of sandy lateritic clay (10–5595 Ωm), extends from 0 to 4 m and grades into dense sand at other locations, reaching a depth of 5.50m. The topsoil exhibits high shear strength (≤150 kg/m 2 ), an allowable bearing pressure of 54 kN/m 2 to 85 kN/m 2 , and a safety factor of 2.5. A 3- to 6-m-thick layer of soft, amorphous clay/peaty clay (0–11 Ωm) lies beneath the topsoil. Grey, medium to very dense sand (0–2387 Ωm), containing infrequent gravel, is found beneath this layer down to 30 m depth. Within the peat/peaty clay, zones containing freshwater show high resistivity responses (83–2380 Ωm), whereas clayey sand with saline water exhibits lower resistivity (0–40 Ωm). The total ground-bearing pressure for the proposed structure is estimated at 225 kN/m 2 . Precast piles reaching 18 m depth, with diameters and safe working loads of 600 mm/1140 kN, 800 mm/2010 kN, or 1000 mm/3150 kN, are recommended for the multi-storey development. This study is novel because it reduces the ambiguity and high cost typically associated with subsurface explorations that preclude the combination of geotechnical and geophysical methods. • Five separate layers were identified from the surface to 30 m depth across the study area. • Peaty layer between 4 and 8 m depth is highly compressible and unsuitable for shallow foundations. • Dense sand layer beneath 11.25 m provides competent material for a high-rise edifice. • Combined geophysical and geotechnical methods enhanced subsurface exploration.

Authors

Institutions

Publication Details

Journal
Kuwait Journal of Science
Published
2026-01-16
DOI
https://doi.org/10.1016/j.kjs.2026.100541
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Subsurface exploration for soil geotechnical properties: Implications for infrastructure design and construction in Victoria Island, Lagos, Nigeria

Sunday Oladele, Bamidele Ruth Faleye, Joseph Oluwagbeja Simeon
Kuwait Journal of Science
Geophysical and Geoelectrical Methods
article

Subsurface exploration for soil geotechnical properties: Implications for infrastructure design and construction in Victoria Island, Lagos, Nigeria

Sunday Oladele, Bamidele Ruth Faleye, Joseph Oluwagbeja Simeon
article en

Abstract

An exploration of subsurface soil properties has been conducted at a proposed construction site in the aquatic city of Lagos, Nigeria, through the integration of geotechnical and geophysical methods. The aim was to characterise the soil properties and assess their implications for the proposed multi-storey infrastructure. Standard Penetration Tests (6), Dutch Cone Penetrometer Tests (14), and dipole-dipole and pole-dipole electrical resistivity imaging were conducted at the site. The topsoil, consisting of sandy lateritic clay (10–5595 Ωm), extends from 0 to 4 m and grades into dense sand at other locations, reaching a depth of 5.50m. The topsoil exhibits high shear strength (≤150 kg/m 2 ), an allowable bearing pressure of 54 kN/m 2 to 85 kN/m 2 , and a safety factor of 2.5. A 3- to 6-m-thick layer of soft, amorphous clay/peaty clay (0–11 Ωm) lies beneath the topsoil. Grey, medium to very dense sand (0–2387 Ωm), containing infrequent gravel, is found beneath this layer down to 30 m depth. Within the peat/peaty clay, zones containing freshwater show high resistivity responses (83–2380 Ωm), whereas clayey sand with saline water exhibits lower resistivity (0–40 Ωm). The total ground-bearing pressure for the proposed structure is estimated at 225 kN/m 2 . Precast piles reaching 18 m depth, with diameters and safe working loads of 600 mm/1140 kN, 800 mm/2010 kN, or 1000 mm/3150 kN, are recommended for the multi-storey development. This study is novel because it reduces the ambiguity and high cost typically associated with subsurface explorations that preclude the combination of geotechnical and geophysical methods. • Five separate layers were identified from the surface to 30 m depth across the study area. • Peaty layer between 4 and 8 m depth is highly compressible and unsuitable for shallow foundations. • Dense sand layer beneath 11.25 m provides competent material for a high-rise edifice. • Combined geophysical and geotechnical methods enhanced subsurface exploration.

Kuwait Journal of ScienceVol. 53(2)
University of Lagos (NG), Nigerian Institute for Oceanography and Marine Research (NG)
Industry, innovation and infrastructure
Openalex Percentile: Top 90%
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.