First Documented Cardiac Functional Recovery Assessed by Dynamic Digital Radiography in Patient With Dilated Cardiomyopathy

tolic dysfunction (ejection fraction: 22%) and dilatation (end-diastolic diameter: 61 mm) (Figure A,B).Cardiac magnetic resonance imaging showed non-specific late gadolinium enhancement.Thus, she was with dilated cardiomyopathy.DDR was performed in supine position during admission using a commercially available mobile radiography system (AeroDR TX Konica Minolta, Inc., Tokyo, W e previously reported that percentage change in pixel value (%pixel value) on the left ventricle (LV) measured by dynamic digital radiography (DDR) reflects LV systolic function. 1We present a case in which DDR was used successfully to monitor clinical course of cardiac failure.A 59-year-old woman presented with acute heart failure.Transthoracic echocardiography (TTE) showed LV sys-

Authors

Institutions

Publication Details

Journal
Circulation Reports
Published
2026-01-16
DOI
https://doi.org/10.1253/circrep.cr-25-0303
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First Documented Cardiac Functional Recovery Assessed by Dynamic Digital Radiography in Patient With Dilated Cardiomyopathy

Naoto Shiomi, Hiroki Okamoto, Noritsugu Matsutani, Hidemitsu Miyatake et al.
Circulation Reports
Cardiac Imaging and Diagnostics
article

First Documented Cardiac Functional Recovery Assessed by Dynamic Digital Radiography in Patient With Dilated Cardiomyopathy

Naoto Shiomi, Hiroki Okamoto, Noritsugu Matsutani, Hidemitsu Miyatake, Yoshihisa Nakagawa
article en

Abstract

tolic dysfunction (ejection fraction: 22%) and dilatation (end-diastolic diameter: 61 mm) (Figure A,B).Cardiac magnetic resonance imaging showed non-specific late gadolinium enhancement.Thus, she was with dilated cardiomyopathy.DDR was performed in supine position during admission using a commercially available mobile radiography system (AeroDR TX Konica Minolta, Inc., Tokyo, W e previously reported that percentage change in pixel value (%pixel value) on the left ventricle (LV) measured by dynamic digital radiography (DDR) reflects LV systolic function. 1We present a case in which DDR was used successfully to monitor clinical course of cardiac failure.A 59-year-old woman presented with acute heart failure.Transthoracic echocardiography (TTE) showed LV sys-

Circulation Reports
Shiga University of Medical Science (JP), Konica Minolta (United States) (US)
Good health and well-being
Openalex Percentile: Top 88%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

First Documented Cardiac Functional Recovery Assessed by Dynamic Digital Radiography in Patient With Dilated Cardiomyopathy — Naoto Shiomi, Hiroki Okamoto, et al. · Circulation Reports (2026) | TGRS Research Map | TGRS