Design, Calibration, and On-Site Validation of an LCVR-Driven Fast-Tunable Lyot Filter for the YOGIS Coronagraph

The Lyot filter, a fundamental element of the Yunnan Observatories Coronagraph Green-line Imaging System (YOGIS) at Lijiang Observatory, utilizes a Liquid Crystal Variable Retarder (LCVR) for swift electrical modulation. This filter allows for precise observations of the coronal green line (Fe XIV, central wavelength 5303 Å) with a narrow full-width at half-maximum (FWHM) of 1 Å and enables rapid adjustment of the transmission band wavelength. This feature aids in capturing the sky background intensity around the green line and images of two line wings (offset by ±0.45 Å from the central wavelength), crucial for determining the green line’s Doppler shift. By employing sky background subtraction and processing line wing images, an improved signal-to-noise ratio (SNR) in coronal green line images is achieved. The YOGIS Lyot filter, an enhancement of the NOrikura Green-line Imaging System (NOGIS) filter, operates at a wavelength of 5303 Å, offers a wavelength tuning range of ±2 Å, and tunes within <60 ms. This study elucidates the filter’s design principles, outlines essential calibration procedures, and validates its performance through on-site observations using the YOGIS.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2026-01-16
DOI
https://doi.org/10.3390/photonics13010076
Primary Topic
Solar and Space Plasma Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design, Calibration, and On-Site Validation of an LCVR-Driven Fast-Tunable Lyot Filter for the YOGIS Coronagraph

S. S. Su, Z. Y. Li, Yu Liu, Mingyu Zhao et al.
Photonics
Solar and Space Plasma Dynamics
article

Design, Calibration, and On-Site Validation of an LCVR-Driven Fast-Tunable Lyot Filter for the YOGIS Coronagraph

S. S. Su, Z. Y. Li, Yu Liu, Mingyu Zhao, Xuefei Zhang
article en

Abstract

The Lyot filter, a fundamental element of the Yunnan Observatories Coronagraph Green-line Imaging System (YOGIS) at Lijiang Observatory, utilizes a Liquid Crystal Variable Retarder (LCVR) for swift electrical modulation. This filter allows for precise observations of the coronal green line (Fe XIV, central wavelength 5303 Å) with a narrow full-width at half-maximum (FWHM) of 1 Å and enables rapid adjustment of the transmission band wavelength. This feature aids in capturing the sky background intensity around the green line and images of two line wings (offset by ±0.45 Å from the central wavelength), crucial for determining the green line’s Doppler shift. By employing sky background subtraction and processing line wing images, an improved signal-to-noise ratio (SNR) in coronal green line images is achieved. The YOGIS Lyot filter, an enhancement of the NOrikura Green-line Imaging System (NOGIS) filter, operates at a wavelength of 5303 Å, offers a wavelength tuning range of ±2 Å, and tunes within <60 ms. This study elucidates the filter’s design principles, outlines essential calibration procedures, and validates its performance through on-site observations using the YOGIS.

PhotonicsVol. 13(1)
Chinese Academy of Sciences (CN), Yunnan Observatories (CN), Southwest Jiaotong University (CN), Nanjing University (CN)
Openalex Percentile: Top 84%
Solar and Space Plasma Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.