Comparison of EWMA, MA, and MQ Under a Unified PBRTQC Framework for Thyroid and Coagulation Tests

<b>Background:</b> Patient-based real-time quality control (PBRTQC) enables continuous analytical monitoring using routine patient results; however, the performance of classical statistical process control (SPC) algorithms varies across analytes, and standardized evaluation and optimization strategies remain limited. To address this gap, this study compared three SPC algorithms-moving average (MA), moving quantile (MQ), and exponentially weighted moving average (EWMA)-within a unified preprocessing framework and proposed a composite performance metric for parameter optimization. <b>Methods:</b> Routine patient results from six laboratory analytes were analyzed using a standardized "transform-truncate-alarm" PBRTQC workflow. Simulated systematic biases were introduced for model training, and algorithm-specific parameters were optimized using a composite metric integrating sensitivity, false-positive rate (FPR), and detection delay. Performance was subsequently evaluated on an independent validation dataset. <b>Results:</b> For most analytes, all three SPC algorithms demonstrated robust PBRTQC performance, achieving high sensitivity (generally ≥0.85), very low false-positive rates (<0.002), and rapid detection of systematic bias. EWMA showed more balanced performance for thyroid-stimulating hormone (TSH), with improved sensitivity and shorter detection delay compared with MA and MQ. The proposed composite metric effectively facilitated clinically meaningful parameter optimization across algorithms. <b>Conclusions:</b> Under a unified preprocessing framework, classical SPC algorithms provided reliable PBRTQC performance across multiple analytes, with EWMA offering advantages for more variable measurements. The proposed composite metric supports standardized, practical, and analyte-adaptive PBRTQC implementation in clinical laboratories.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-01-16
DOI
https://doi.org/10.3390/diagnostics16020288
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of EWMA, MA, and MQ Under a Unified PBRTQC Framework for Thyroid and Coagulation Tests

Y. Hu, Xiaoqi Li, Wenyi Ding, Chaochao Ma et al.
Diagnostics
Clinical Laboratory Practices and Quality Control
article

Comparison of EWMA, MA, and MQ Under a Unified PBRTQC Framework for Thyroid and Coagulation Tests

Y. Hu, Xiaoqi Li, Wenyi Ding, Chaochao Ma, Qian Chen, Ling Qiu, Banjiu Zhaxi
article en

Abstract

<b>Background:</b> Patient-based real-time quality control (PBRTQC) enables continuous analytical monitoring using routine patient results; however, the performance of classical statistical process control (SPC) algorithms varies across analytes, and standardized evaluation and optimization strategies remain limited. To address this gap, this study compared three SPC algorithms-moving average (MA), moving quantile (MQ), and exponentially weighted moving average (EWMA)-within a unified preprocessing framework and proposed a composite performance metric for parameter optimization. <b>Methods:</b> Routine patient results from six laboratory analytes were analyzed using a standardized "transform-truncate-alarm" PBRTQC workflow. Simulated systematic biases were introduced for model training, and algorithm-specific parameters were optimized using a composite metric integrating sensitivity, false-positive rate (FPR), and detection delay. Performance was subsequently evaluated on an independent validation dataset. <b>Results:</b> For most analytes, all three SPC algorithms demonstrated robust PBRTQC performance, achieving high sensitivity (generally ≥0.85), very low false-positive rates (<0.002), and rapid detection of systematic bias. EWMA showed more balanced performance for thyroid-stimulating hormone (TSH), with improved sensitivity and shorter detection delay compared with MA and MQ. The proposed composite metric effectively facilitated clinically meaningful parameter optimization across algorithms. <b>Conclusions:</b> Under a unified preprocessing framework, classical SPC algorithms provided reliable PBRTQC performance across multiple analytes, with EWMA offering advantages for more variable measurements. The proposed composite metric supports standardized, practical, and analyte-adaptive PBRTQC implementation in clinical laboratories.

DiagnosticsVol. 16(2)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking University (CN), Peking Union Medical College Hospital (CN)
Openalex Percentile: Top 87%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.