Comparison of EWMA, MA, and MQ Under a Unified PBRTQC Framework for Thyroid and Coagulation Tests
<b>Background:</b> Patient-based real-time quality control (PBRTQC) enables continuous analytical monitoring using routine patient results; however, the performance of classical statistical process control (SPC) algorithms varies across analytes, and standardized evaluation and optimization strategies remain limited. To address this gap, this study compared three SPC algorithms-moving average (MA), moving quantile (MQ), and exponentially weighted moving average (EWMA)-within a unified preprocessing framework and proposed a composite performance metric for parameter optimization. <b>Methods:</b> Routine patient results from six laboratory analytes were analyzed using a standardized "transform-truncate-alarm" PBRTQC workflow. Simulated systematic biases were introduced for model training, and algorithm-specific parameters were optimized using a composite metric integrating sensitivity, false-positive rate (FPR), and detection delay. Performance was subsequently evaluated on an independent validation dataset. <b>Results:</b> For most analytes, all three SPC algorithms demonstrated robust PBRTQC performance, achieving high sensitivity (generally ≥0.85), very low false-positive rates (<0.002), and rapid detection of systematic bias. EWMA showed more balanced performance for thyroid-stimulating hormone (TSH), with improved sensitivity and shorter detection delay compared with MA and MQ. The proposed composite metric effectively facilitated clinically meaningful parameter optimization across algorithms. <b>Conclusions:</b> Under a unified preprocessing framework, classical SPC algorithms provided reliable PBRTQC performance across multiple analytes, with EWMA offering advantages for more variable measurements. The proposed composite metric supports standardized, practical, and analyte-adaptive PBRTQC implementation in clinical laboratories.
Authors
- Y. Hu
- Xiaoqi Li (ORCID: https://orcid.org/0000-0003-1443-0151)
- Wenyi Ding
- Chaochao Ma
- Qian Chen
- Ling Qiu
- Banjiu Zhaxi
Institutions
- Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
- Peking University (CN)
- Peking Union Medical College Hospital (CN)
Publication Details
- Journal
- Diagnostics
- Published
- 2026-01-16
- DOI
- https://doi.org/10.3390/diagnostics16020288
- Primary Topic
- Clinical Laboratory Practices and Quality Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00