In Vitro Wire Tension in Circular External Fixation Frames

Circular frames are applied to control fracture and osteotomy mechanics, which is dependent on frame design.As the clinical application of these devices is individualised, clinical performance can be difficult to compare from one case to another.In fine wire constructs, stability is dependent on wire tension, which can degrade over time.As such, wire tension is a parameter that surgeons may attempt to keep consistent between cases or indeed adapt to the clinical situation.However, there is little evidence regarding what variables in fixator application might influence this.The aim of the study was to monitor wire tension in an in vitro symmetrical circular frame construct using strain gauge instrumented wires and to use these to investigate the clinical factors in assembly and use of a frame that may be associated with tension loss.The results demonstrated that variability in wire tension was associated with the application of the tensioner itself, along with wire slippage associated primarily with the bolt torque used to tighten the ends of the wires to the frame.These two variables could easily lead to a 50% variation in the actual wire tension achieved.Surprisingly, under dynamic loading, despite an initial loss in tension due to slippage, wire tension generally remained constant and was not significantly different between wires applied with different wire pre-tensions after the initial three cycles.A calibrated tensioner with a high initial tension (110 kg), along with a controlled wire clamp bolt torque (14 Nm), is required to achieve the most consistent frame performance.

Authors

Publication Details

Journal
Strategies in Trauma and Limb Reconstruction
Published
2026-01-16
DOI
https://doi.org/10.5005/jp-journals-10080-1653
Primary Topic
Mechanical stress and fatigue analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Wire Tension in Circular External Fixation Frames

Anthony Howard, William Bolton, Alice M. Benton, Charlotte Merrell et al.
Strategies in Trauma and Limb Reconstruction
Mechanical stress and fatigue analysis
article

In Vitro Wire Tension in Circular External Fixation Frames

Anthony Howard, William Bolton, Alice M. Benton, Charlotte Merrell, Paul Harwood, Pete Culmer, Isobel S Burridge
article en

Abstract

Circular frames are applied to control fracture and osteotomy mechanics, which is dependent on frame design.As the clinical application of these devices is individualised, clinical performance can be difficult to compare from one case to another.In fine wire constructs, stability is dependent on wire tension, which can degrade over time.As such, wire tension is a parameter that surgeons may attempt to keep consistent between cases or indeed adapt to the clinical situation.However, there is little evidence regarding what variables in fixator application might influence this.The aim of the study was to monitor wire tension in an in vitro symmetrical circular frame construct using strain gauge instrumented wires and to use these to investigate the clinical factors in assembly and use of a frame that may be associated with tension loss.The results demonstrated that variability in wire tension was associated with the application of the tensioner itself, along with wire slippage associated primarily with the bolt torque used to tighten the ends of the wires to the frame.These two variables could easily lead to a 50% variation in the actual wire tension achieved.Surprisingly, under dynamic loading, despite an initial loss in tension due to slippage, wire tension generally remained constant and was not significantly different between wires applied with different wire pre-tensions after the initial three cycles.A calibrated tensioner with a high initial tension (110 kg), along with a controlled wire clamp bolt torque (14 Nm), is required to achieve the most consistent frame performance.

Strategies in Trauma and Limb ReconstructionVol. 20(2)
Affordable and clean energy
Openalex Percentile: Top 86%
Mechanical stress and fatigue analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In Vitro Wire Tension in Circular External Fixation Frames — Anthony Howard, William Bolton, et al. · Strategies in Trauma and Limb Reconstruction (2026) | TGRS Research Map | TGRS