Occupational Exposure to Environmental Aerosols from Heated Tobacco Products in Japanese Catering Venues: a Pilot Study

A study was conducted in six Tokyo venues, each with separate nonsmoking and heated tobacco product (HTP)-use areas. Additionally, three of the venues had a smoking booth within the HTP-use area. Airborne nicotine was used as a specific marker to assess the occupational exposure of waitstaff in these venues. In nonsmoking areas, area monitoring generally demonstrated airborne nicotine levels below the detection limit or marginally exceeded it, except for one venue (maximum 0.278 μg/m3). In HTP-use areas, nicotine levels ranged from 0.237 to 2.16 μg/m3 (minimum–maximum range, median 0.681 μg/m3). For personal exposure in nonsmoking areas, 15 out of 19 8 h time-weighted averages were below the limit of quantification (LOQ). In cigarette smoking booth-equipped venues, most personal exposure measurements of the waitstaff entering HTP-use areas were quantifiable at low levels. Whereas the venues without cigarette smoking booths showed lower exposure levels, with 58% of samples below LOQ. All parameters for working environment control class assessment defined by the Japan Society of Occupational Health were below 1% of the threshold limit value for nicotine (TLV, 500 μg/m3). Area monitoring data were used to statistically model the predictive nicotine distribution, indicating a 0.7% probability of exceeding 5 μg/m3. The findings of this study support that separated nonsmoking and HTP-use areas, active mechanical ventilation, and negative pressure in HTP-use areas to direct airflow help to reduce waitstaff’s occupational exposure to nicotine (used as proxy for HTP environmental emissions) below 1% TLV as well as help prevent HTP aerosols from entering nonsmoking areas.

Authors

Institutions

Publication Details

Journal
ACS Chemical Health & Safety
Published
2026-01-16
DOI
https://doi.org/10.1021/acs.chas.5c00188
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occupational Exposure to Environmental Aerosols from Heated Tobacco Products in Japanese Catering Venues: a Pilot Study

María Gómez Lueso, Maya I. Mitova, Sachie Yamaji, Samuel Kleinhans et al.
ACS Chemical Health & Safety
Indoor Air Quality and Microbial Exposure
article

Occupational Exposure to Environmental Aerosols from Heated Tobacco Products in Japanese Catering Venues: a Pilot Study

María Gómez Lueso, Maya I. Mitova, Sachie Yamaji, Samuel Kleinhans, Catherine Goujon-Ginglinger, Yvonne S. K. Khoo
article en

Abstract

A study was conducted in six Tokyo venues, each with separate nonsmoking and heated tobacco product (HTP)-use areas. Additionally, three of the venues had a smoking booth within the HTP-use area. Airborne nicotine was used as a specific marker to assess the occupational exposure of waitstaff in these venues. In nonsmoking areas, area monitoring generally demonstrated airborne nicotine levels below the detection limit or marginally exceeded it, except for one venue (maximum 0.278 μg/m3). In HTP-use areas, nicotine levels ranged from 0.237 to 2.16 μg/m3 (minimum–maximum range, median 0.681 μg/m3). For personal exposure in nonsmoking areas, 15 out of 19 8 h time-weighted averages were below the limit of quantification (LOQ). In cigarette smoking booth-equipped venues, most personal exposure measurements of the waitstaff entering HTP-use areas were quantifiable at low levels. Whereas the venues without cigarette smoking booths showed lower exposure levels, with 58% of samples below LOQ. All parameters for working environment control class assessment defined by the Japan Society of Occupational Health were below 1% of the threshold limit value for nicotine (TLV, 500 μg/m3). Area monitoring data were used to statistically model the predictive nicotine distribution, indicating a 0.7% probability of exceeding 5 μg/m3. The findings of this study support that separated nonsmoking and HTP-use areas, active mechanical ventilation, and negative pressure in HTP-use areas to direct airflow help to reduce waitstaff’s occupational exposure to nicotine (used as proxy for HTP environmental emissions) below 1% TLV as well as help prevent HTP aerosols from entering nonsmoking areas.

ACS Chemical Health & SafetyVol. 33(2)
Philip Morris International (Switzerland) (CH), Sanno Medical Center (JP)
Good health and well-being
Openalex Percentile: Top 88%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines