A novel polydopamine/hydroxyapatite composite coating on Mg alloy with excellent corrosion resistance and biocompatibility

A novel composite coating with excellent corrosion resistance and biocompatibility on Mg–3Al–2Sn alloy was prepared by combining the advantages of polydopamine (PDA) and hydroxyapatite (HAP), and was investigated by scanning electron microscopy, electrochemical test, and in vitro cellular tests. The results showed that the PDA/HAP composite coating with a thickness of 19.7 μm covers the underlying PDA cracks and Mg matrix and effectively reduces the corrosion current density of the alloy from 266 to 1.53 μA cm −2 . The PDA/HAP coating exhibits excellent corrosion resistance with a 99.42 % corrosion inhibition efficiency, superior to the majority of developed HAP composite coatings to date. Meanwhile, it maintains stable pH and the lowest hydrogen evolution (4.7 ± 0.05 mL/cm 2 ) after 7 days of immersion in SBF, and retains a dense intact structure without damage. Additionally, the PDA/HAP coating exhibits excellent biocompatibility, as MC3T3-E1 cells cultured in its extract show numbers and morphologies close to those of the control group, maintain stable viability over 5 days, and indicate no significant cytotoxicity. Finally, the bonding and corrosion protection mechanisms of the PDA/HAP composite coating were discussed. • Corrosion resistant and biocompatible PDA/HAP composite coating prepared on Mg alloy. • The corrosion inhibition efficiency of the PDA/HAP coating on Mg alloy is 99.42 %. • PDA/HAP coating shows good long-term corrosion resistance during immersion in SBF. • Cell viability test results for PDA/HAP-modified alloys remain above 90 %. • The bonding and corrosion mechanisms of PDA/HAP composite coating are discussed.

Authors

Institutions

Publication Details

Journal
Materials Today Chemistry
Published
2026-01-16
DOI
https://doi.org/10.1016/j.mtchem.2026.103367
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel polydopamine/hydroxyapatite composite coating on Mg alloy with excellent corrosion resistance and biocompatibility

Xiaobo Zhang, Zhi Hu, Zhaochen Yu, Honggun Song et al.
Materials Today Chemistry
Magnesium Alloys: Properties and Applications
article

A novel polydopamine/hydroxyapatite composite coating on Mg alloy with excellent corrosion resistance and biocompatibility

Xiaobo Zhang, Zhi Hu, Zhaochen Yu, Honggun Song, Hanqing Mei, Zhenlin Liao
article en

Abstract

A novel composite coating with excellent corrosion resistance and biocompatibility on Mg–3Al–2Sn alloy was prepared by combining the advantages of polydopamine (PDA) and hydroxyapatite (HAP), and was investigated by scanning electron microscopy, electrochemical test, and in vitro cellular tests. The results showed that the PDA/HAP composite coating with a thickness of 19.7 μm covers the underlying PDA cracks and Mg matrix and effectively reduces the corrosion current density of the alloy from 266 to 1.53 μA cm −2 . The PDA/HAP coating exhibits excellent corrosion resistance with a 99.42 % corrosion inhibition efficiency, superior to the majority of developed HAP composite coatings to date. Meanwhile, it maintains stable pH and the lowest hydrogen evolution (4.7 ± 0.05 mL/cm 2 ) after 7 days of immersion in SBF, and retains a dense intact structure without damage. Additionally, the PDA/HAP coating exhibits excellent biocompatibility, as MC3T3-E1 cells cultured in its extract show numbers and morphologies close to those of the control group, maintain stable viability over 5 days, and indicate no significant cytotoxicity. Finally, the bonding and corrosion protection mechanisms of the PDA/HAP composite coating were discussed. • Corrosion resistant and biocompatible PDA/HAP composite coating prepared on Mg alloy. • The corrosion inhibition efficiency of the PDA/HAP coating on Mg alloy is 99.42 %. • PDA/HAP coating shows good long-term corrosion resistance during immersion in SBF. • Cell viability test results for PDA/HAP-modified alloys remain above 90 %. • The bonding and corrosion mechanisms of PDA/HAP composite coating are discussed.

Materials Today ChemistryVol. 52
Nanchang University (CN), Nanjing Institute of Technology (CN)
Openalex Percentile: Top 88%
Magnesium Alloys: Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel polydopamine/hydroxyapatite composite coating on Mg alloy with excellent corrosion resistance and biocompatibility — Xiaobo Zhang, Zhi Hu, et al. · Materials Today Chemistry (2026) | TGRS Research Map | TGRS