Endovascular Rescue After Jugular Vein Catheter Complications: A Case Report

BACKGROUND Internal jugular vein catheterization is a primary vascular access method for hemodialysis; however, it carries a risk of complications. Common adverse events include arterial puncture, hematoma, and pneumothorax; rarer but more serious events involve catheter malposition into major arteries. Despite real-time ultrasound guidance, anatomic factors, technical considerations, and patient-specific characteristics may contribute to these adverse outcomes. CASE REPORT A 64-year-old man with end-stage renal disease and decompensated heart failure required urgent dialysis. During ultrasound-guided placement of a 12.5-Fr dual-lumen catheter, the sheath inadvertently traversed the jugular vein, entered the right subclavian artery, and advanced to the aortic arch. Computed tomography angiography confirmed the catheter course. In a hybrid operating room, the arterial injury was successfully managed using an endovascular suture device. This approach achieved hemostasis without additional venous injury and avoided the need for open surgical repair. No evidence of impaired intracranial blood flow was observed during follow-up. Dialysis was resumed via femoral access the following day; the patient was discharged without complications. This case highlights a rare but life-threatening complication of a routine procedure. CONCLUSIONS Real-time ultrasound guidance does not eliminate the risk of serious catheter misplacement during internal jugular vein cannulation. When inadvertent subclavian artery cannulation occurs, an endovascular suture device may provide a rapid and minimally invasive solution avoiding further venous compromise and posing no risk to cerebral perfusion. These findings support consideration of endovascular closure as an option for the management of iatrogenic arterial injuries, particularly in high-risk patients who are unsuitable for major surgery.

Authors

Institutions

Publication Details

Journal
American Journal of Case Reports
Published
2026-01-15
DOI
https://doi.org/10.12659/ajcr.950898
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endovascular Rescue After Jugular Vein Catheter Complications: A Case Report

Chenyang Shen, Yilun Zhou, Akehu Alemasi, Yong Gong et al.
American Journal of Case Reports
Central Venous Catheters and Hemodialysis
article

Endovascular Rescue After Jugular Vein Catheter Complications: A Case Report

Chenyang Shen, Yilun Zhou, Akehu Alemasi, Yong Gong, Xia Ding, Genhuan Yang
article en

Abstract

BACKGROUND Internal jugular vein catheterization is a primary vascular access method for hemodialysis; however, it carries a risk of complications. Common adverse events include arterial puncture, hematoma, and pneumothorax; rarer but more serious events involve catheter malposition into major arteries. Despite real-time ultrasound guidance, anatomic factors, technical considerations, and patient-specific characteristics may contribute to these adverse outcomes. CASE REPORT A 64-year-old man with end-stage renal disease and decompensated heart failure required urgent dialysis. During ultrasound-guided placement of a 12.5-Fr dual-lumen catheter, the sheath inadvertently traversed the jugular vein, entered the right subclavian artery, and advanced to the aortic arch. Computed tomography angiography confirmed the catheter course. In a hybrid operating room, the arterial injury was successfully managed using an endovascular suture device. This approach achieved hemostasis without additional venous injury and avoided the need for open surgical repair. No evidence of impaired intracranial blood flow was observed during follow-up. Dialysis was resumed via femoral access the following day; the patient was discharged without complications. This case highlights a rare but life-threatening complication of a routine procedure. CONCLUSIONS Real-time ultrasound guidance does not eliminate the risk of serious catheter misplacement during internal jugular vein cannulation. When inadvertent subclavian artery cannulation occurs, an endovascular suture device may provide a rapid and minimally invasive solution avoiding further venous compromise and posing no risk to cerebral perfusion. These findings support consideration of endovascular closure as an option for the management of iatrogenic arterial injuries, particularly in high-risk patients who are unsuitable for major surgery.

American Journal of Case ReportsVol. 27
Capital Medical University (CN), Beijing Tian Tan Hospital (CN)
Good health and well-being
Openalex Percentile: Top 88%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.