Deadbeat Control for a Three-Phase Solar T-Type Inverter and Comparison with PI Control

This paper proposes a deadbeat-based current control method for a three-phase T-type solar inverter to improve transient performance and harmonic immunity compared with conventional PI control. The control framework adopts a double-loop structure, in which the photovoltaic (PV) voltage is regulated by a perturb-and-observe (P&O)-based maximum power point tracking (MPPT) algorithm in the outer loop, while d–q axis currents are controlled in the inner loop. A performance comparison between the PI control and the proposed deadbeat control was conducted using an ESS T-type inverter with an inner current control loop, and the results were validated through combined simulation and experimental investigations. Under experimental conditions, when the d-axis reference current was stepped from 5.2 A to 9.2 A, the deadbeat controller achieved a transient settling time of approximately 1.89 ms, representing a 47.5% reduction compared to the 3.6 ms observed with the PI control. Furthermore, under 7th harmonic injection (0.225), the total harmonic distortion (THD) was reduced from 12.9% to 4.3%. These results demonstrate that the proposed deadbeat control strategy provides faster transient response and enhanced robustness against harmonic disturbances in three-phase T-type inverter applications.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-01-14
DOI
https://doi.org/10.3390/en19020417
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deadbeat Control for a Three-Phase Solar T-Type Inverter and Comparison with PI Control

Il Song Kim, HanJoon Jang
Energies
Multilevel Inverters and Converters
article

Deadbeat Control for a Three-Phase Solar T-Type Inverter and Comparison with PI Control

Il Song Kim, HanJoon Jang
article en

Abstract

This paper proposes a deadbeat-based current control method for a three-phase T-type solar inverter to improve transient performance and harmonic immunity compared with conventional PI control. The control framework adopts a double-loop structure, in which the photovoltaic (PV) voltage is regulated by a perturb-and-observe (P&O)-based maximum power point tracking (MPPT) algorithm in the outer loop, while d–q axis currents are controlled in the inner loop. A performance comparison between the PI control and the proposed deadbeat control was conducted using an ESS T-type inverter with an inner current control loop, and the results were validated through combined simulation and experimental investigations. Under experimental conditions, when the d-axis reference current was stepped from 5.2 A to 9.2 A, the deadbeat controller achieved a transient settling time of approximately 1.89 ms, representing a 47.5% reduction compared to the 3.6 ms observed with the PI control. Furthermore, under 7th harmonic injection (0.225), the total harmonic distortion (THD) was reduced from 12.9% to 4.3%. These results demonstrate that the proposed deadbeat control strategy provides faster transient response and enhanced robustness against harmonic disturbances in three-phase T-type inverter applications.

EnergiesVol. 19(2)
Korea National University of Transportation (KR), Hyundai Engineering (South Korea) (KR), Hyundai Research Institute (KR)
Affordable and clean energy
Openalex Percentile: Top 87%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.