Design and tolerance of polychromatic multi-material freeform gradient-index phase corrector plates

Previous studies have demonstrated the potential of multi-material gradient-index (MMGRIN) optical elements in polychromatic imaging applications, yet few have explored the manufacturability of such elements. The ability to control polychromatic aberrations with MMGRIN elements is demonstrated through a design study of polychromatic MMGRIN phase-corrector plates utilizing freeform refractive-index-profile definitions. A single MMGRIN element design corrected for three wavelengths is presented. A Monte Carlo trial-based tolerance method is used to determine the manufacturing precision required for optimum yield. The MMGRIN designs and their tolerance results are then compared with equivalent phase corrector plate designs based on refractive freeform surfaces. The results show that the MMGRIN design has less strict precision requirements than the equivalent refractive freeform surface design.

Authors

Publication Details

Journal
Optics Continuum
Published
2026-01-15
DOI
https://doi.org/10.1364/optcon.583347
Primary Topic
Advanced optical system design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and tolerance of polychromatic multi-material freeform gradient-index phase corrector plates

Greg Schmidt, Yuchen Wu
Optics Continuum
Advanced optical system design
article

Design and tolerance of polychromatic multi-material freeform gradient-index phase corrector plates

Greg Schmidt, Yuchen Wu
article en

Abstract

Previous studies have demonstrated the potential of multi-material gradient-index (MMGRIN) optical elements in polychromatic imaging applications, yet few have explored the manufacturability of such elements. The ability to control polychromatic aberrations with MMGRIN elements is demonstrated through a design study of polychromatic MMGRIN phase-corrector plates utilizing freeform refractive-index-profile definitions. A single MMGRIN element design corrected for three wavelengths is presented. A Monte Carlo trial-based tolerance method is used to determine the manufacturing precision required for optimum yield. The MMGRIN designs and their tolerance results are then compared with equivalent phase corrector plate designs based on refractive freeform surfaces. The results show that the MMGRIN design has less strict precision requirements than the equivalent refractive freeform surface design.

Optics ContinuumVol. 5(2)
Openalex Percentile: Top 87%
Advanced optical system design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.