Direct calibration of resistance thermometers between 10 K and 25 K by absolute acoustic gas thermometry in helium

We have implemented absolute acoustic gas thermometry at 10 K, 13.8 K, 19 K and 24.6 K to evaluate the performance of this primary method for the direct thermodynamic calibration of capsule-type resistance thermometers, including both platinum and rhodium-iron types. Our implementation is based on speed of sound measurements in helium at a single pressure, chosen in the range 65 to 130 kPa, with non-ideality corrections relying on accurate ab initio calculations of the thermodynamic properties. The overall accuracy achieved in the determination of the thermodynamic temperature T varies between a minimum of 0.1 mK at 13.8 K to a maximum of 0.2 mK at 24.6 K. From the acoustic results and the calibration of thermometers on the international temperature scale ITS-90 providing T90, we determined the differences (T-T90), finding them in good agreement with the 2022 consensus estimates within the combined uncertainties. These results include a determination of the thermodynamic temperature at the triple point of neon TNe = (24.55502 ± 0.00030) K. This new value of TNe is consistent with other recent determinations obtained with various primary methods. Finally, we provide an example of a rapid, yet accurate, simplified thermodynamic calibration procedure. This article is part of the Theo Murphy meeting issue 'The redefined kelvin: progress and prospects'.

Authors

Institutions

Publication Details

Journal
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Published
2026-01-15
DOI
https://doi.org/10.1098/rsta.2025.0043
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct calibration of resistance thermometers between 10 K and 25 K by absolute acoustic gas thermometry in helium

Dario Imbraguglio, R. M. Gavioso, Peter P. M. Steur
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Calibration and Measurement Techniques
article

Direct calibration of resistance thermometers between 10 K and 25 K by absolute acoustic gas thermometry in helium

Dario Imbraguglio, R. M. Gavioso, Peter P. M. Steur
article en

Abstract

We have implemented absolute acoustic gas thermometry at 10 K, 13.8 K, 19 K and 24.6 K to evaluate the performance of this primary method for the direct thermodynamic calibration of capsule-type resistance thermometers, including both platinum and rhodium-iron types. Our implementation is based on speed of sound measurements in helium at a single pressure, chosen in the range 65 to 130 kPa, with non-ideality corrections relying on accurate ab initio calculations of the thermodynamic properties. The overall accuracy achieved in the determination of the thermodynamic temperature T varies between a minimum of 0.1 mK at 13.8 K to a maximum of 0.2 mK at 24.6 K. From the acoustic results and the calibration of thermometers on the international temperature scale ITS-90 providing T90, we determined the differences (T-T90), finding them in good agreement with the 2022 consensus estimates within the combined uncertainties. These results include a determination of the thermodynamic temperature at the triple point of neon TNe = (24.55502 ± 0.00030) K. This new value of TNe is consistent with other recent determinations obtained with various primary methods. Finally, we provide an example of a rapid, yet accurate, simplified thermodynamic calibration procedure. This article is part of the Theo Murphy meeting issue 'The redefined kelvin: progress and prospects'.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering SciencesVol. 384(2312)
Istituto Nazionale di Ricerca Metrologica (IT)
Openalex Percentile: Top 90%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.