Late Dislocation of Adaptive Proximal Scaphoid Implant: A Case Report
Abstract The adaptive proximal scaphoid implant (APSI) is an ovoid and unfixed partial scaphoid prosthesis used to replace the proximal pole of the scaphoid to prevent scaphoid nonunion, advanced collapse wrist, or scapholunate advanced collapse wrist, two challenging pathologies for hand surgeons. We described a case of a late dislocation of APSI after a high-energy trauma after 17 years the hemiarthroplasty, which we treated with a new APSI replacement and double-layer capsuloplasty. Dislocation is the most common complication in this type of prosthesis, which occurs most of the time within 3months, as an early complication. We reviewed the literature discussing the problem of dislocation in this type of surgery. Numerous strategies have been suggested for these pathologies, but the APSI is a valid alternative in young patients who need a rapid recovery, and it is an alternative to more invasive surgery.
Authors
- Roberto Adani
- Julien Teodori
- Caterina Marra (ORCID: https://orcid.org/0000-0002-3511-8127)
- Augusto Marcuzzi
- Gianluca Sapino
Institutions
- University of Parma (IT)
- Azienda Ospedaliero-Universitaria di Modena (IT)
Publication Details
- Journal
- Journal of Wrist Surgery
- Published
- 2026-01-14
- DOI
- https://doi.org/10.1055/a-2781-2771
- Primary Topic
- Orthopedic Surgery and Rehabilitation
- Type
- article
- Field-Weighted Citation Impact
- 0.00