Progress of acoustic gas thermometry using a cylindrical resonator at temperatures up to 809 K

We are extending acoustic gas thermometry (AGT) to temperatures up to 809 K with low uncertainties to measure the difference between the thermodynamic temperature T and the temperature T90 on the International Temperature Scale of 1990 (ITS-90). A cylindrical resonator was machined from a Ni-Cr-Fe alloy and acoustic and microwave waveguides welded to the cavity's endplates transmitted sound and microwaves to and from the cavity. A long-stemmed standard platinum resistance thermometer (LSPRT) measured T90 at the cavity wall. Pure argon gas flows continuously through the cavity to minimize the effects of desorption from the cavity walls. The resonator was hung in a pressure vessel surrounded by a radiation shield, a heat pipe and a furnace. We measured the acoustic resonant frequencies in argon in the range 580 to 809 K with relative standard uncertainty (3-5)×10-6. We applied a second-order boundary-layer correction to these frequencies. Each microwave resonance frequency was measured with a relative standard uncertainty of 3×10-7. The inconsistency between four independent microwave modes was 2.2×10-6 at 809 K, which contributed an uncertainty of 3.6 mK to the determination of T. The inconsistencies were not temperature dependent, which showed the structural stability of the resonator from room temperature to 809 K. This article is part of the Theo Murphy meeting issue 'The redefined kelvin: progress and prospects'.

Authors

Institutions

Publication Details

Journal
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Published
2026-01-15
DOI
https://doi.org/10.1098/rsta.2024.0454
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Progress of acoustic gas thermometry using a cylindrical resonator at temperatures up to 809 K

Michael R. Moldover, Keith A. Gillis, Xiaofeng Lu, Jintao Zhang et al.
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Calibration and Measurement Techniques
article

Progress of acoustic gas thermometry using a cylindrical resonator at temperatures up to 809 K

Michael R. Moldover, Keith A. Gillis, Xiaofeng Lu, Jintao Zhang, Xiaojuan Feng, Li Xing, Liu Xu
article en

Abstract

We are extending acoustic gas thermometry (AGT) to temperatures up to 809 K with low uncertainties to measure the difference between the thermodynamic temperature T and the temperature T90 on the International Temperature Scale of 1990 (ITS-90). A cylindrical resonator was machined from a Ni-Cr-Fe alloy and acoustic and microwave waveguides welded to the cavity's endplates transmitted sound and microwaves to and from the cavity. A long-stemmed standard platinum resistance thermometer (LSPRT) measured T90 at the cavity wall. Pure argon gas flows continuously through the cavity to minimize the effects of desorption from the cavity walls. The resonator was hung in a pressure vessel surrounded by a radiation shield, a heat pipe and a furnace. We measured the acoustic resonant frequencies in argon in the range 580 to 809 K with relative standard uncertainty (3-5)×10-6. We applied a second-order boundary-layer correction to these frequencies. Each microwave resonance frequency was measured with a relative standard uncertainty of 3×10-7. The inconsistency between four independent microwave modes was 2.2×10-6 at 809 K, which contributed an uncertainty of 3.6 mK to the determination of T. The inconsistencies were not temperature dependent, which showed the structural stability of the resonator from room temperature to 809 K. This article is part of the Theo Murphy meeting issue 'The redefined kelvin: progress and prospects'.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering SciencesVol. 384(2312)
National Institute of Standards and Technology (US), National Institute of Metrology (CN)
Openalex Percentile: Top 90%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Progress of acoustic gas thermometry using a cylindrical resonator at temperatures up to 809 K — Michael R. Moldover, Keith A. Gillis, et al. · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences (2026) | TGRS Research Map | TGRS